My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2122 RUCKER AVE 2016-01-01 MF Import
>
Address Records
>
RUCKER AVE
>
2122
>
2122 RUCKER AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2017 8:07:09 PM
Creation date
3/8/2017 8:06:55 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2122
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> � rr�' .n <br /> . "J <br /> ., <br /> �; J <br /> REPAZR .`�iFECIFICnTIG:15 i�iJD LIST OF SOORIC TO BE EID <br /> � q �� ` �� <br /> ,/ /�- --• � � <br /> .,ddress : �� � � /.f�/� Cy Paqe .,, ! r <br /> 3. Rcx�f & Insulation Strip �11 building roof areas, except ttie roof <br /> over the po:ch in the southeast corner and the lower roof across the <br /> back, down to the spaced sheathing. insert R-11 batt insulation <br /> b�tween the rafters in the slopEd ceiling spaces only over unit #4 (top <br /> f oor unit) . 1-covide at least i" clearance between the top side of the <br /> insulation and the twttmn side of the spaced board sheathing �bove. <br /> Contractor may have to lay 1" r. ?." wood strips on the middle of each <br /> batt to provide air space. Contrantor to note there is some insulation <br /> work called out in item #4. <br /> Cover the stripped roof aceas Mith 1/2" CDX plywood and iasten <br /> three-tab fiGerglass shinyl.es. 'Itiis roofing work to include roofing <br /> the roof "eyebraws" and al.s�� �o close off the openings where birds are <br /> able �o enter. owner hzs had problems with birds nesting in the upper <br /> ,��ithwest "eyebrow". New st�ingles to have at least a 20 year written <br /> r -.canty, contractor to register the warranty with the roofing <br /> mo„ufacturer and leave information with the own�r. Owner to select new <br /> coofing color. <br /> Owner to straighten out exi�ting gutters after the roofing work has <br /> been completed. Contractor to prote<:t the gutters during the work. <br /> I Ownec to repair all dama�ed cailing �ireas resulting fran roof repairs <br /> above. �he new roof wo�k shall be perfocmed as per the manufactucer's <br /> installation specifications and .in ca�liance with the requirements of <br /> the Uniform Building Code, 1985 eciticn. <br /> $ <br /> q. Framinq. Drywall & Doocs All work in this item to take place in <br /> nit pl. Remove walls and add 2" x. •9" (16" centers) framed walls as <br /> indicated on the attached plan. All wall & celling areas worked on in <br /> this item to be fin9.shed by the contractor in pceparation fo� the ownec <br /> to paint. Note, some walls to be removed are already called out in <br /> item N1. All new interior doors to be pcehung, prefinished hollow core <br /> mahogany doors aith �chlage passage sets or equal. A�1 new exterior <br /> doocs to be prehung insulated six panel steel doors w±.th entry lock <br /> sets and single cylinder dead bolts, Schlage or equal. <br /> New middle bedroom. Remove Yhe bathroom north and east walls making <br /> this area, and the storage behind, a21 one romn (new bedroam) . Frame <br /> in a drop ceiling, aEter removal of heat piping etc. at the ?' 6" line <br /> above the floor. Faise remaining plumbing and gas pioing as <br /> necessacy. Insulate with R-11 batts between the new ceiling joists and <br /> cover with 1/2" gypsum wallboard. Insulate all opened up exterior <br /> walls with R-11. Frame in around the exposed caste iron waste lines <br /> along the north side of the room. Close oEf doorways and frame closet <br /> as indicated. Install new 2' 8" bedroom interior door and two 3' 0" <br /> closet doors. Prep all bedroom c+alls and cover all walls with i/2" <br /> ' gypsum wallboard. Tape and spackle entire room leaving a light <br /> textured finish for owner to paint. <br /> New east bedroom. FUrr out along the east concrete wall with treatec' <br /> 2" x 4" studs un 16" centers leaving =pace between the wood and the <br /> concrete. Insulate between these studs and all opened up exterior <br /> walls with R-11 batts. Frame in new closet as indicated. Rnise <br /> overhead pltmibing and gas lines and re�nove; all old heat system piping <br /> only as necessary to frame in a new drop ceiling at the 7' 6" height. <br /> Insulate between the c�rop ceiling Eraming with R-11 uatts. Cover all <br /> bedroom ceiling and walls with 1/2 gyps�nn walli�oard, tape and spackle <br /> with a light texture Einish for owner to paint. Install prefi�iished <br /> mahogany bifold doors with hardware complete in new closet opening. <br /> InstalJ. 2' B" room entry door off ha'_lway and a new 2' 6" exterior <br /> steel door in outside opening. <br />
The URL can be used to link to this page
Your browser does not support the video tag.