My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2320 RUCKER AVE 2018-01-01 MF Import
>
Address Records
>
RUCKER AVE
>
2320
>
2320 RUCKER AVE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2019 2:48:45 PM
Creation date
3/8/2017 8:27:34 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2320
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> . , , ._ <br /> 9ctober 7 1974 5i`������� <br /> ' \kt�itiijc;i�N� <br /> I X'�k ll"t I l l('I 1( <br /> (�SfK'li1�.41 k'flll�l <br /> Joe LeGault, Administrator �q�•K �,y <br /> LeGault Nursing Home � <br /> 2320 Rucker Avenue � <br /> Everett, ti'ashington f <br /> Re: H.F.C.U. 1i74421-1092-1 <br /> LeGault Nursing Home <br /> Additions to 2tao Wards <br /> Dear Mr. LeGault: <br /> Following is a reviec. of the p1Ans for referenced pro�ect prepared by <br /> A. L. Scheine, Architect, received September 19, 1974. These drawings <br /> have not been approved for the reasona noted in the review. Please <br /> restudy and resubmit two corrected sets of drawings. <br /> Review of the above submission has been compieted pursuant to Chapter <br /> WAC 248-14 of the Nursing Home Codified Rulea, Regnlatione and Standards <br /> adopted by the Washington State Board of Health on March 11, 1960, as <br /> amended. Section WAC 248-14-100 of the Codified Rules requires that <br /> dravings shall be approved before construction begine and such plans and <br /> specificatione be used as conatruction contract documents. <br /> The review findings are divided into parts, as follows: <br /> 1. Show the location of aeparated, enclosed, reasonable-sized storage <br /> facilities for patient clothing and personal belon�ings for each <br /> patient. WAC 248-14-220(13) <br /> 2. If the existing seven-bed ward is converted to two separate rooms <br /> as shown on the plan, "new cunstruction" requirements would have to <br /> be met for both rooma. This would lnvolve several items which the <br /> rooms would fail to meet such as SS square feet of usable floor <br /> finace ner bed, three feet of clear space around each bed except at <br /> the head, and traffic from one bedroom through another bedroom in <br /> order to reach the toilet and bathing facilities ��ould be prohi- <br /> bited. Tt is suggested that the seven-bed ward renain as an exist- <br /> ing seven-bed ward. This could be done by reducin� the extent of <br /> the partition in the middle of the room by ending it 4 feet, 4 <br /> inches f:om the inside wall and instead of two doors opening into <br /> the hallway, retain only one door. See tdAC 248-14-17.0(2) (a)6(d) <br /> 3. Tha nurses' call system eignal devices will have to be relocated for <br /> each bed. Please show on the plan. WAC 248-i4-110(3) <br /> • <br /> � � � � � dC� � <br /> �,r-ni m sr���v�cr-. r,��,vz: c•-, ��T 10 1974 <br /> ���� � �� �`� � �� � � �� �� � CITY OF EVERETT <br /> .� o c �; � o . , :�n �,. � <br /> Inspection � <br />
The URL can be used to link to this page
Your browser does not support the video tag.