retardant-treated lumber is not permitted). The effected walls should be shown on the <br /> plans as well -�s the construcNon of the parapet in accordance with Section 709.4. <br /> Commont noted. Please refer to the revised roof plan indicating the locations of <br /> all required rated parepets. <br /> 10. In fire-resistive exterior wall construction, the fire-resistive raNng shall be <br /> maintained for such walls passing through attic areas or other areas containing <br /> concealed spaces per Section 709.3.1 The floor/ceiling assemblies should be shown <br /> as having the two hour fire-resistive construction continue through that vad space at <br /> the interconnection belween the �valls and floors. Note that the TJI's shown within the <br /> floor cavity in Details �0 8 II/S-16 ere not sufficient to maintain the fire-resistive <br /> construcHon requirements of the wall assembly. <br /> Comment noted. Please refer to the revised roof plan indicating the locations of <br /> all required rated parapets. <br /> 11. The North and South exterior walls are set back irom the property lines <br /> incrementally. The following comments apply to ihose walls: <br /> b). As the ceiling forms the protective membrane for fire-resistance, the assemblies <br /> and their supporting horizontal stnictural members are required to be individually fire <br /> protected when the members support directly appiied loads from a floor and roof, or <br /> more than one floor. The required fire resistance shall not be less than that required for <br /> individual protecNon of inembers (rivo-hour fire-resistance to hold up the rivo hour <br /> exterior wall). Additionally, all walls supporting the lwo-hour fire-resistive (horizontal) <br /> assembly will be required to be of similar fire-resistive construction. Details are <br /> required and all effected wall and flooNceiling assemblies should be individually <br /> called out in plan and section. Section 704.2.6 <br /> Comment noted. Please refer to revised drawings showing new details and <br /> reference notes. <br /> c). The above mentioned walls will require a parapet if located less than 20' from the <br /> property line end the roofs are either combustibie construction or less than two hour <br /> construction. Section 709.4.1 <br /> Interior Court. Note that only new code sections are shown if not already mentioned <br /> above. <br /> 1. The bridge within the main court spans between two buildings which have been <br /> separated by an area separation wall. This condition violates the requirements set <br /> forth in Section 504.6,1 that a complete separation is required. However, also stated in <br /> that section is that portions of buildings separated by the area separation wall may be <br /> considered separate buildings. A connection between two adjacent buildings is <br /> permitted by the u6lization of a pedestrian walkway as outlined in SecHon 409. Based <br /> ,� �r,l�:�l uv\.ilkl � I� ��,�� ,K ��� ���������,-r,�, <br /> . . .�,.,.��;�,�, ,,:�.::; , .., t.��nu ain rdr, ra� <br /> ���mrr:U.: ;�n nu v bn.cM1-e� <br /> 11��1�P�IIII�G�'���iiRD��p�f'GR��I���If,l!�I11��;�uii�G1��:IRCHITCCTI'RC �If���ER�.I�I�C�II�(IR[�IGI�IGRIN�C�E�Ii;��!��1D���D�Gf <br />