My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2522 RUCKER AVE 2018-01-01 MF Import
>
Address Records
>
RUCKER AVE
>
2522
>
2522 RUCKER AVE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/3/2019 8:57:37 AM
Creation date
3/8/2017 9:01:48 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2522
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
492
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
would be required to be placed for opening protection requirements per Section <br /> 503.3. <br /> b). The addition of the decks create floor area, per definition Section 207. Based on <br /> the distance to property line requirements, this floor area is required to be protected by <br /> two-hour, fire-resistive exterior wall construction. In essence, what is cunently shown is <br /> equivalent to unprotected openings within ri�e exterior wall. Table 5-A <br /> Comment noted. Please refer to revised drawings showing decks removed. <br /> Area has been converted to 11oor space with wall protection as required by code. <br /> c). Simila�ly, the decks and storage units on the west elevallon �epresent floor area <br /> that is required to be protected by exterior walls and opening protection. <br /> This item hes been resolved per our meeting. <br /> 6. Projections beyond the exterior wall shall comply with Section 705 and shall not <br /> extend beyond a point one third the distance to the property line from an assumed <br /> vertical plane located where fire•resistive protection of openinge is first required due to <br /> location on property. Specifically, the projections beyond the exterior walls may be <br /> located no close:than 13'-4' to the respective property lines (provided the <br /> requirements in comment #5b are satisfied). <br /> Projections have been limited to attached non-combustable steel balcony rails <br /> as detailed per revised drawings. <br /> 7. Combustible projections located where openings are not permitted or where <br /> protecdon of openings is required shall be of one-hour fire-resistive or heavy-tlmber <br /> construcHon conforming to Section 605.6. Details of the projections should bo <br /> provided on the plans. Section 705 <br /> Comment noted. Please refer to revised drawings showing new details and <br /> reference notes. <br /> 8. The sum of the area of openings in exterior walls required to be protected due to <br /> distance from property lines should not exceed 50 peroent of the total area of the wall <br /> in each story. Due to the large amount of glezing shown, the East and West walls <br /> should have a typical floor level (2,3 or 4) analyzed and submitted to show <br /> compliance. Section 503.22 <br /> Comment noted. Please refer to the attached tabulatlon sheet indiceting <br /> conformance. <br /> 9. Parapet wails are required on every exterior wall less than 20' from the property <br /> line unless the walis will tertninate at roofs of not less than twahour fire-resistive <br /> construction, or roofs constructed entirely of noncombustible materials (note that fire <br /> li�l ili�. i `I11V �if:I�.I�.T ,"��� �� ��, ��������,��� <br /> ti� i i �,� i ai f�a� <br /> '.e ,. .. . . ,. �,', �� . � u ��911�i1\�vr.M1e� <br /> � III�CRP!Il�il������EaIiRD��iCf!GRl�llf,[ipl�l!�IIIi��1�ED���I;IRCIIITECTGREiII��RP�111�C111'�ORDp�11GR�PIIICD��II��q1SCIPEDE�1 <br />