Laserfiche WebLink
Comment noted. Please refer to revised drawings showing new detaiis <br /> engineered specifically to meet this requirement. <br /> 3. A corr,plete section showing all constn�ction segments of the ASW i�cluding the <br /> well to foundation, wall to floor, and wall to attic condidons should be provided on the <br /> plans. <br /> Comment noted. Please refer to revised drawings showing new deffiils and <br /> reference notes. <br /> 4. As wood framing has been chosen for the surrounding structure, differential <br /> settlement caused by the disparity between the shrinkage of the wood, and non <br /> shrinkage of other materials within the ASW (if utilized) should be detailed. <br /> Comment noted. Please refer to revised drawings showing new detafls and <br /> reference notes. <br /> 5. Every door penetrating an area separation wall should be shown in plan and cross <br /> referenced to the door and hardware schedules to be a three-hour rated automadc <br /> closing fire assembly. Section 504.6.2 <br /> Comment noted. Please refer to revised drawings showing new door <br /> and hardware schedule. <br /> 6. The requirements of automatic-closing fire assemblies shouid be stated on the <br /> plans and tied-into the Hardware Schedule per Sections 713.2 and 713.6.1 <br /> Comment noted. Please refer to revised drawings showing new door <br /> and hardware schedule. <br /> 7. The area separation wall should extend through the concealed roof space to the <br /> outer edges of the projected overhang. This should be detailed on the plans.Section <br /> 504.6.3 <br /> Comment noted. Please refer to revised drawings showing new deffiils and <br /> reference notes. <br /> 8. A detail should be provided which shows that the area separation wall terminates <br /> 30 inches above the roof or extends to the bottom of the underside of the roof <br /> sheathing for a roof provided with a minimum of two-hour fire-resistive construction. <br /> Section 504.6.4 <br /> Comment noted. Please refer to revised drawings showing new deteils and <br /> reference notes. <br /> 9. If a parapet is used, details should be provided in accordance with SecNon 504.6.5 <br /> III� ��I.�ll `I'I\1�n���I�i� ��\r,lf��il .11�ll lll��u'����li�li�'.�A\ <br /> \I..f'�. \1'.I..�.�.1.,' .... ,. . \Il�nl��. •1.l1i'lil!11t1,.1�f'.�'.1\ <br /> �I�ER�III�II;i'll�lfiRDE?1Gf!GRIf1�C[�Eilf,l!��II��Pf Df�IGI';IRCIIITECTC��RE fIIU�Rf�II1l1�GIII�IpRD�IGI'GRI�If.��IG1���l�f,{�DC�IGI� <br />