My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2522 RUCKER AVE 2018-01-01 MF Import
>
Address Records
>
RUCKER AVE
>
2522
>
2522 RUCKER AVE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/3/2019 8:57:37 AM
Creation date
3/8/2017 9:01:48 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2522
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
492
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
As access to each building's exiting system is only provided through the area <br /> separation walls, the area separa6on walls are then also horizontal exits. Based on <br /> these observations, the comments below should be addressed. <br /> 1. A ho�zontal exit should not serve as the only exit hom a portion of a building per <br /> Section 1008.1. Exitlng from units B, F, I and J on the soutli side of the 'alley' building <br /> do not comply. <br /> Note confirmed, please note revised configurs�tion of area separatlon walls. <br /> 2. The Garden Deck and Unit A types below arQ accessed through pedest�ian <br /> walkways. Pedestrian walkways conforming to the requirements of a horizontal exit <br /> may be used as a required exit per the ezcep6on to Section 409.7, however a <br /> horizontal exit should not serve as the only exit from a porton of a building. Section <br /> 1008.1 <br /> The Unit has been eliminatr3d and the Garden Deck has been reloceted. <br /> 1. Discharge areas should be provided. The capacity shall be determined by allowing <br /> 3 square feet of net c+ear floor area for each occupant to be accommodated, not <br /> including areas of stairs, elevators, dwelling units, or othc�r shaits or courts. Based on <br /> the current occupant load of Floor 6", each exit is required to serve an occupant load <br /> of 36. The minimum size of discharge area on each side of both area separation walls <br /> should �e shown as 108 square feet. Sectlon 1008.3. <br /> Comment noted, due to the above reconfiguraUon we are cuRendy compliant <br /> with this requirement. <br /> 'Note that this is based on the requirements of Section 1002 and includes the <br /> Garden Deck occupant load of 49. As floors have different occupant loads, the <br /> discharge areas should be based on the occupant load served by each floor. <br /> Ana f�paration Walls <br /> 1. An area separation wall (ASW) must be a complete wall (rom foundation to <br /> parapet, and not from floor to floor as stated by note on Detail 8/A7.3. It should be <br /> designed so that a failure on one side oi the ASW will not result in the failure effectlng <br /> the ASW, or stnacture on the opposite side of the ASW. Section 504.6.1 <br /> Comment noted. Please refer to revised drawings showing new details and <br /> reference notes. <br /> 2. UL Design No. U435 is specifically stated to be a non bearing wall. Calculations <br /> should be provided which show that assembly's ability to carry its own weight, plus <br /> superimposed weight, for the 6 stories of wall construction or en approved bearing <br /> wall assembly should be provided. SecUon 504.6.1 <br /> I�'�'i, '��I�.�l ��.I��,I'� `l�f'E��.I . ��.���o- .�x�� un:w:n�..�,,.r,�, <br /> e"�n�n �.n:u i��v�c,ni ra� <br /> . .. . . .,. � 1l��nrw� �r:n lt�t Pq.tl��nr.9.n <br /> III��R�.lI1�G�'l�I�DRD�+1Cf!GRI�ICD�I��ILl11�C��D��I�Ir1RCHITECTURE II(lC��.111��C!11f�ORD�GIIGR�N�C���G'�i��l1S��PED�IGI <br />
The URL can be used to link to this page
Your browser does not support the video tag.