construction detail. <br /> Cort�,:ient noted. Please refer to revised drawings indicadng requirement via <br /> reference notes and plan markings. <br /> 9. Wall type GA WP 3370 shown in Detail 7/A7.3 should be noted to heve horizontal <br /> bracing at mid height per the listing. <br /> Comment noted. Nlease refer to revised drawings indicatlng compliance via <br /> referenae notes and details. <br /> 10. Detail 7/A7.3 notes that the air space between unit party walls is to be increased <br /> as required to position plumbing stacks within iraming at plumbing walls. As this may <br /> not be possible to do after the wall is built, the required space for plumbing should be <br /> detailed before such walls are in place. Note also that many plumbing walls are also <br /> shear walls and wall offsets or on-site changes may reduce the structural integrity of <br /> the lateral for�ce resisting system. Such proposals should also be submitted to tha <br /> Engineer of Record. <br /> Comment Noted. We will be working closely with the Generel Contrector and <br /> Structurai �ngineer m ensure the final plumbing design accomodates required shear <br /> walls as well as indicaNng a minimum wall depth of 5 1/2" adjacent to bathroom <br /> plumbing. <br /> 11. Section BB/A5.2 shows a bEam suppordng the exterior wall of the southem stair <br /> enclosure. This beam (and structure supF�rting the beam) should be shown as <br /> individually protected for two-hour fire resistance. SecNon 704.2.6 <br /> Comment noted. Please refer to revised drawings indicatlng compliance via <br /> reference notes and details. <br /> 12.Fire blocking should be shown at the interconnections of the floor and wall <br /> assemblies in detail 9/S-16. Sec!ion 708.2 <br /> Comment noted. Please refer to revised st�uctural drawings indicadng modified <br /> detail. <br /> 13. Details of intenor non-bearing partitions �vithin the apartments should be provided. <br /> Section 601.5.2.2 <br /> Comment noted. Please re(er to revised drawings indicaNng compliance via <br /> reference notes and details. <br /> 14.Detaiis of the connections and construction of the jurv�ture between the <br /> balconies/decks and the iloors/walls should be provided. <br /> II�I P,I;S111U\ )If;F;I�:T i,�;�'I� :i"inii:i�':o'i�"'"�ia; <br /> :i��.�. Und.�.:�: ..�' I�n 11in'�n.rdr,0.741L'n.lCnnr.}'a� <br /> II��RP�III�f,i6�1(�;�C�ICfIGR�IC���GI�I�IIii�C�ftD�IG1;:IRCI�IITECTURC il���,�I1�GI11�101'iD��GI!GR��IG��1CfI�l1i�C��Daw�� <br />