Cortxnent noted. Please refer to revised drawings indicadng compliance via <br /> reference notes and details. <br /> 15.Eave overhangs shall be constructed for one-hour requir3ments in areas where <br /> opening orotection is required. Section 705 <br /> Comment noted. Please refer to revised drawings indicadng compliance via <br /> reference notes and details. <br /> 16. The bearing walls should be clearly delineated on the plans for the purpose of <br /> providing thorough penetratlon protection. Section 709.6 <br /> Comment noted. Please refer to revised floor plans indicating locadons of <br /> bearing wells. <br /> 17.It shoufd be detailed on the plans how fire-resistive walls requiring protected <br /> openings and bearing walls are protected with fire stops requiring F and/or T ratings <br /> for both membrene and through penetrations. Details and information should be <br /> provided on the plans, along with the appropriate approval numbers. Sections 709.6, <br /> 709.7 & 714 <br /> Comptete manufacturer provided fire safeing specifications will be issued for <br /> Building Plan Check review prior to the start of construction. <br /> 18. Details should be provided which show the method of protection for all proposed <br /> penetrations of the ceiling membrane per Section 710.2. <br /> Comment noted. Please refer to revised drawings indicadng requirements per <br /> reference notes and details. <br /> 19. Details of the clothes dryer and kitchen stove exhaust duct shafts should be <br /> provided per Section 710.2. Note that dampers are not perrnitted for these ducts per <br /> the UMC. <br /> Comment noted. Please refer to revised drawings indicating locadons of duct <br /> runs as well as reference notes and assembly details. <br /> 20. Floors should be continuous without openings or penetrations unless it is noted <br /> and detailed on the plans that penetratlon of floors will be protected with through <br /> penetration fire stops installed to provide an F or T ratlng, as well as a listing showing <br /> each proposed fire stop. Section 710.3 <br /> Complete manufacturer provided fire safeing specifications will be issued for <br /> Building Plan Check review prior to the start of conshuction. <br /> 21. Per Section 713.13, a sign shall be displayed permanently near or on each <br /> �i,�� ���.��� �.�1�11����:�.� Y.�III: 9h� Iq: 1H;11�.�.t�.i� <br /> I\rrrll Ir��l lln.�u.ui I.o <br /> . . . . . , \mno.�.a�u il�Pr,n��i�r.Tn� <br /> IfI�R�.H�I��'���I11�h!i!RP��!bI�I;RIPiiiC[if�IGl��IIp�1f�.DE�IG�� IRI;IIITI;CTORE ilf��1ER�.�I1��G'11�IQRD��IIGR�PNICDf�I�II��I�C�PEDCi�f <br />