My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2522 RUCKER AVE 2018-01-01 MF Import
>
Address Records
>
RUCKER AVE
>
2522
>
2522 RUCKER AVE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/3/2019 8:57:37 AM
Creation date
3/8/2017 9:01:48 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2522
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
492
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Comment noted. Please refer to revised drawings indicatlng requirements per <br /> reference notes and details. <br /> 26.Balconies, landings, courts, occupied roois and similar surfaces exposed to the <br /> weather and sealed undemeath should be waterproofed and sloped a minimum of <br /> t/4' per foot, or ponding calculadons shou�d be submitted. Details of construcdon are <br /> required. Sections 1506.18 1605.6 <br /> Corn�nent noted. Please refer to revised drawings indicating requirements per <br /> reterence notes end details. <br /> 27. Drains and overflow drains for the roof and courts should be detailed and <br /> provided where required in accordance with section 1506. <br /> Comment noted. Please refer to revised drawings indicatlng requirements per <br /> reference notes and details. <br /> 28. A minimum of a Class B root classification should be shown. Section 1503 <br /> Comment noted. Please refer to revisod drawings indicadng requirements per <br /> reference notes and details. <br /> 29. An attic access opening (minimum 22 inches by 30 inches) should be provided <br /> with a minimum clear headroom of 30 inches for each attic space. The opening should <br /> be shown on ihe plans and be located in a hallway, corridor or other accessible <br /> location. Note that a rated hatch will be required to penetrate ihe protective ceiling <br /> membrane. Section 1505.1 <br /> Comment noted. Please refer to revised floor plans indicadng locadons of <br /> access hatches. <br /> 30. Calculations should be provided which show the required amount of attic <br /> ventllation has been pro�vided. "Bird Blockirg" (deteil 6/S-16) will require additional <br /> ventilation such as ridge or gable end vents. Required 1!4 inch corrosion resistant <br /> rnetal mesh shall be specified. Note that the mesh wili reduce the efficiency to 15°/a of <br /> the gross opening. Attic ventilation may not be taken from areas where opening <br /> protection is required. All vendng IocaHons shoufd be shown on the roof plans. <br /> Comment noted. Please refer to revised roof plan, details and calculations. <br /> 31. Main runners, cross furring, and hangers should be specified on the plans and <br /> shown to be in conformance with Table 25-A for the suspended ceiling shown in the <br /> exercise room. Section 2504.4 <br /> Comment noted. Please refer to revised drawings indicatlng reSuirements per <br /> reference notes. <br /> I�I I II I.>I ',I?J A �I kl'.I.1� .�.��n� ,w:ax an a����,-��r.,� <br /> � � � . ... . . L.1 \I�1�1liII.11�IlIIII,I�I���(1111'.'��T\ <br /> 11���,11'�II��;�I!�i�!!�R[if�tiIC17GR�ICDE�I�����lI�,IPED�IGI�I;IRCHITEC�'URE 1��1�f��Il��GiII�QR��CI1GR�fl��CD�1G:fI�IIDSG��D�VG1� <br />
The URL can be used to link to this page
Your browser does not support the video tag.