2522 RUCKER AVE 2018-01-01 MF Import
>
Address Records
>
RUCKER AVE
>
2522
>
2522 RUCKER AVE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/3/2019 8:57:37 AM
Creation date
3/8/2017 9:01:48 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2522
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
492
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
( Geotxhnic�l Enginxring RepoR <br /> ' Gudener Group Condominiums <br /> luly 16, 1997 <br /> iNCA File No.209297 <br /> Pege 9 <br /> Ibelow adjacent grade of 2.0 feet for columns end 1.5 feet for continuous footings. Using these depths <br /> and minimum footing widths of 1.5 feet for continuous foundations and 2 feet for squarc foundations,we <br /> Irecommend usiRg an allowzble bearing capacity of 3,Q00 pounds per square foot (ps�. A onathird <br /> increase in the above a!lowable bearing prcssure may be used when considering short-term trensitory <br /> I wind or seismic loads. Higher bearing capacities can be provided for specitic locations and designs, if <br /> desired. We should be contacted to review sp�:ific plans if higher bearing capacities are nceded. <br /> � <br /> The above bearing pressures assume lhat the foundation excavations have been cleaned of soft or <br /> I loosened soil prior to placing concrete. If the foundation areas arc to be exposed to wet conditions, we <br /> recommend that they be overexcavated and covered with a blanket of 6 inches of compacted struct..ral <br /> fill consisting of a clean(less than 5 percent fines) sand and gravel. An altemative is to pour a 2- inch- <br /> Ithick Iean-mix concrete slab over the foundation areas. We recommend that the foundation areas be <br /> evalueted by us prior to placing the pit-run covering or pouring the concrete. <br /> IAlthough swctural laading �nformation was not available at the time of this study, based on our <br /> I experience with similar structures supported on similar soil conditions and for the above allowable soil <br /> bearing pressures, we estimate that thc maximum total post-construction settlement should be 3/4 of an <br /> inch or less, and ihat the differential settlement across the building width should be 1/2 inch or less. <br /> fSettlements are expected to be elastic in nature and to occur as the building loads are placed. <br /> I Retriuing Walls <br /> The lateral pressure acting on retaining walls is dependent on the nature and density of the soil behind <br /> f the wall, the amount of laterel wall movement which can occur as backfill is placed, and the inclination <br /> � of the backfill. For walls that are free to yield at the top at least one thousandth of the height of the well, <br /> soil pressures wiq be less than if movement of the top is restricted. We recommend that walls be <br /> � desi ned usin an active ressure e uivalent to a fluid wei hin 35 unds r cubic foot ror <br /> � B B P 9 8 B P� Pe (P� <br /> yielding walls and 50 pcf for non-yielding walls. These are for walls with a level backfill. The effects of <br /> suroharges, such as traffic or foundation loads should be 30 or 50 peroent of the suroherge for yielding <br /> and non-yielding walls,respectively. <br /> The above wall pressures assume proper drainege and compaction of the wa11 backfill. Wall backfill <br /> should consist of free-draining granular fill. All backfill for subgrade walls should be compacted to <br /> between 90 and 92 percent of the maximum dry density detertnined in accordance with ASTM D 155 7. <br /> Care�horld be taken to prevent the buildup of excess lateral soil pressures due to overcompaction of the <br /> Ibackfill behind the wall. 'Chis can be accomplished by placing the backfill located within 18 to 24 inches <br /> � NELSON-COUYRETTE &ASSOGATES, ING <br />