Laserfiche WebLink
' ,. : . <br /> Plan Checl� No. B 57457 <br /> Mue6 16, 1998 <br /> Page 2 of 2 <br /> 4. A door and window sched�k ahould be provided on the plaa4 which shows at a miaimum the <br /> type, size, fire ruing and hudware propos�. Section 1063.3 <br /> 5. The plaas should indicau how required atnutural and fue-resisdve integriry will be <br /> maintained w6eie peneorations will be made for electrical, mechanical, plumbiug �nd <br /> communicadon conduits, pipes and similar systems. Section 106.33 <br /> 6. Details for tt�rough penetration a�xl �mbrane penetradon protecdon should be provided. <br /> 7. The ezercise room should be reclassificd as a B Occupancy. Section 304.1 <br /> 8. T6e shearwall key-plans should be completed. <br /> 9. If wood stud walls and bearing partitions are useJ, they shall not suppon more tl�an two ftoors <br /> and a roof uniess an ac�alysis shows tLat shrinkage of the wood framing will not twve adverse <br /> effects on t!x savcture or any plumbiog, elxtrical or mechanicsl sysoems, or �ther equipment <br /> installed theroin due to excessive shrinlrage or differontial movements caused t�y shrinkage . <br /> The analysis should also show that the rooi drainage system eai the forcgoing systems or <br /> eq�ipment will not be adversely affxted or, as an altemate, svch systems sh�tl be desigad W <br /> accommodate the differential shridnge or movements. Secdon 2318 <br /> Prepare a response letter showing where each item in this corrocdon lemer is addressed on ttx ptan set. <br /> Upon resubmittal of the drawings, your applicadon will be given prioriry and pl�n review will <br /> recommence. <br /> All nequired submittals shall be of sufficient detail and contain sufficie� informadon to ensure that tbe <br /> proposed structure will be consmuted in compliance with all adopad codes. <br /> Sincemly, <br /> ��� ���--' <br /> dey <br /> Associate Engineer <br /> n���� <br />