Laserfiche WebLink
b). The length, height, diameter, wall clearance, and position of the two grab bars at <br /> the water closet should be dimensioned on the plans. Section 1106.11.53 <br /> c). Where towel bars, dispensers, mirrors, shelves, dryers, etc. are provided, at least <br /> one of each should be shown to be within 40"of the tloor. Secdon 1106.11.8 <br /> d). The lavatory should have a mas;imum rim height of 34", as well as a 29"high by <br /> 30" wide minimum cleazar.ce anderneath. Dimensions should be provided. Section <br /> 1106.11.7.3 <br /> e). Drain pipes and hot water pipes should be sl.own recessed and insulated or <br /> guarded to prevent contact. Section I 106.11.7.4 <br /> 6. Signs for the visually impaired should be provided to identify public toilet rooms, <br /> stai�s, and elevators. Where other signs are provided, they should also comply. <br /> � Sections 1103.2.4& 1106.16 <br /> , <br /> � Accessible Dwelling Units <br /> 1. Details of the grab bars at the Type A unit bathtubs should be provided. A grab baz is <br /> required on the end wall over the drain, and 2 bars are required at the back wall. <br /> � Section 1106.11.9.3 <br /> ; 2. The seat for the Type A unit bathtub should be shown. Secuon 1106.11.9.2 <br /> ` 3. A shower spray unit, wi!� a hose at least 60 inches long, that can be used as a fized <br /> ' shower he: i or as a hand-held shower, shall be provided and located offset laterally <br /> from the cleu floor space between the open edge of the tub and the mid-point of the <br /> tub and shall comply with Section 11063. Section 1106.11.9.4 <br /> 4. The kitchens in the Type A wits should have a 30" z 24" counter with a maximum <br /> height of 34". the space beneath the counter should be atleast 29" high, 30" wide, <br /> and 19"-25"deep. Sections 1 I06.2.3 &1106.12.2 <br /> 5. All dwelling units in buildings with elevators which do not mat the standards for <br /> Type A units should be designed as Type B units. Sections I 103.1.8.2& 1106.27 <br /> 6. A 30" x 48" maneuvering space should be provided in one bathroom in each Type B <br /> unit. The door swing may not encroach into this space. Secdon 1106.27.1 ez 3 <br /> 7. In each Type B unit, a cleaz floor space should be provided at one toilet per Section <br /> 1106.11.5.1. This requires a 42" lateral clearance forn� the centerline of the wnter <br /> closetto thc nearest obstruction on one side, and an l8" clearance on the opposite <br /> side. An accessible or adaptable lavatory may be located in t6e clear floor space if the <br /> 17 <br />