Laserfiche WebLink
1. Although the mu:hanical system and review is under a separate pemtit, the following <br /> items concern the conswcdon of the building and should be addrossed for the <br /> building peratit. <br /> 2. Residendal structures greater than four stories in height shall comply w`�h 3xtion <br /> 304 (VIAQ) for outdoor sir suppl�requirements. Compliance with this section shall <br /> be demonstrated tivough engineering calculations or performance testing. Secdon <br /> 302.1 Washington State Vendlapon Code <br /> 3. If the unit water heaters have nonrigid water connections and aze over 4' in height, <br /> they should be shown anchored or strapped to resist earthquake motion. Secdon <br /> 304.4 UMC <br /> 4. It should be specified whether the dwellings will be provided with gas or elxtric <br /> based heat and hot-water. Gas applia�es will ceyuire combusdon air supply which <br /> will be myuired to be detailed. Secdons 703.4 and 706 UMC <br /> 5. Combustion-air ducts shall not be installed so as to pass firough construcdon where <br /> firo darr�pers ar+e required. Section 704.2 UMC <br /> 6. Domesdc clothes dryers should be exhausted to the outside. The dryer moisturc duct <br /> should not excxd a total combined horizontal and veRical length of 14'. Secdon <br /> 504.3.2 <br /> 7. The plans should state whene fire dampers wili be required per Section 713.10,UBC. <br /> 8. The plans shoald state where smoke dampen will be required per Secdon 713.11, <br /> UBC. <br /> 9. There should be a note that the factory-built fireplaces should be listed and installed <br /> in accordance with the listing. Section 302.2 and 304.1 UMC <br /> 10.The chimney/vents shaft for the fireplaces should be detailed and s6own to have <br /> � adequate room for all vents into the shaft. <br /> END OF COMMENTS <br /> 19 <br />