Laserfiche WebLink
Engineer's InspeCtion of �he Froperty Locatcd ai Page 12 <br /> 2615 and 2626 Rucker Avenue, [vcrett. Washington <br /> siding tends to swell and buckie, occasionally even puiling oui its fasteners. I;s <br /> weatherproofing qualities tend to be poorer than those oi good wood siding. The fastening <br /> of some of the sheets to the structure does not appear to meet normal standards. The <br /> s:.rfaCe shows excessive deterioration at the joints which is normat for the material. <br /> A foundation addition has been installed along the Nont of lhe building; it shows some <br /> settlement at the southeaSt corner. This installation is typical where a wood skirting is <br /> insl811ed below grade. There is a greater than normal possibility of �oncealed decay in the <br /> covered skiAing. <br /> This siding is not adequately weatherproof and can�ot be made so with reasonabie repairs. I <br /> recommend that it be replaced. <br /> The building design does not provide good , <br /> eave protection to the walls as illustrated in �� � �%4 <br /> the sketch. This tends to accelerate the � 1 <br /> deterioration of paint, Sidi�g, windows and ' <br /> doors. It leakage develops in the r�of the �� �� <br /> probabiiity oi the deveiopment of interior ' �'� ' <br /> damage and of structurai decay are much ' / �% <br /> higher that it the building has good eave � � =I <br /> overh��ngs. r <br /> i <br /> PAI�f�: The paint on tha trim is �o d.K OVt4NSH� y.ypp �,,,� ,,,�,,,,,,, <br /> detQriorated. Aderyuate weather proteCtion Ef fect of aave Overhang <br /> is no longer provided. The suriaces shouid <br /> be properly prepared and repainted. <br /> FRONT ENTRY COVER: The roof covering is metal that appears to be i� serviceable <br /> Condition. The metal support posts at the corners are rusted through in plaoes and may not <br /> have adequate strength for the intended use. <br /> DECK: It has a continuous wooden tloor (as opposed to spaced-boards���etl eY.. <br /> - -• � ng. This type otfloor tends to be rt5ore subjecf tobuckti�sg-�lyd'd€c�y-The---- ` <br /> sMucturai members do not appear to be pressure treated against decay. <br /> A rooi is provided. While a roof is a great help in protecting against deterioration, it is not so <br /> eflecttve as to eliminate the need for proper construction and maintenance. <br /> The deck has experienced some settlement, particularly next to the building. This is usually a <br /> result Of poor construction practice. Althouyh such serilement usually stops after a few years, <br /> there is no assurance that it wili do so. <br /> There iS an interior area below it, so any leakage through th? iloor �a-ili cause interior damage. <br /> Such leakage oiten develops in such structures. <br />