My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3619 RUCKER AVE 2018-01-02 MF Import
>
Address Records
>
RUCKER AVE
>
3619
>
3619 RUCKER AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2022 2:26:31 PM
Creation date
3/8/2017 11:40:53 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3619
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
217
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
H <br />aye <br />.'aye `I 1 <br />C" <br />SEPA #131-89 <br />K� <br />EFD PC$ 89-294 <br />O = <br />o <br />3600 RUCKER <br />H H <br />H <br />CITY OF EVERETT <br />fiDQTRS FIRE STATION <br />mos <br />TO: DON WOOD <br />H <br />g <br />FROM: SAM PRESTON <br />a. <br />O <br />DATE: 9-20-89 <br />H <br />zy <br />1. FIRE FLOW -- 33,314 <br />SQ FT - <br />TYPE 2 1 HOUR - SPRINKLERED- <br />H <br />y <br />1500 GPM. <br />C u <br />w <br />2. HYDRANTS -- EXISTIN <br />HYDRANTS <br />ARE ADEQUATE. <br />'zz <br />H <br />to <br />3. ACCESS -- OK. <br />H O <br />ti <br />4. SPRINKLER SYSTEM -- <br />MUST BE <br />INSTALLED IN ACCORDANCE WITH <br />UNIFORM <br />BUILDING CODE STANDARD 38-1 AND <br />OR NFPA <br />STANDARD 13, <br />PLANS MUST BE SUBMITTED TO THE BUILDING DEPARTMENT AND/OR THE <br />FIRE DEPARTMENT FOR REVIEW AND APPROVAL FOR BOTH THE <br />UNDERGROUND FIRE MAIN AND THE SPRINKLER SYSTEM. HYDROSTATIC <br />TESTS AND FLUSHING TESTS ARE TO BE PERFORMED WITH WITNESS BY <br />THE FIRE PREVENTION BUREAU. CONTRACTORS MATERIAL AND TEST <br />CERTIFICATES FOR THE UNDERGROUND PIPING AND THE SPRINKLER <br />SYSTEM MUST BE COMPLETED AND SUBMITTED TO THE FIRE DEPT. <br />��� 5. FIRE SAFETY PRACTICES DURING CONSTRUCTION SHALL BE IN <br />COMPLIANCE WITH ARTICLE 87 OF THE UNIFORM FIRE CODE, 1988 <br />EDITION. <br />1 6. UNDERGROUND STORAGE TANKS REQUIRE: <br />I. A FIRE DEPARTMENT PERMIT FOR INSTALLATION. <br />II. SUBMIT PLANS TO THE FIRE PREVENTION BUREAU WHICH SHOW: <br />A. SIZE, LOCATION, AND PRODUCT STORED FOR EACH TANK. <br />B. SPECIFICATIONS ON TANK AND PIPING MATERIALS. <br />w C. CORROSION PROTECTION, IF APPLICABLE. <br />i D. PIPING DIAGRAM INCLUDING FILL OPENINGS AND VENT <br />LINES AND OPENINGS. <br />E. DETAIL AND LOCATIONS OF LEAK DETECTION. <br />F. SPECIFICATIONS FOR ANY SPECIAL EQUIPMENT. <br />of I 7. PORTABLE FIRE PROTECTION -- PORTABLE FIRE PROTECTION SHALL BE <br />PROVIDED WITHIN 75' TRAVEL DISTANCE OF ALL PORTIONS OF <br />_ COMBUSTIBLE CONSTRUCTION DURING CONSTRUCTION. <br />8. PREMISES ID -- A LEGIBLE AND VISIBLE ADDRESS SHALL BE <br />POSTED ON THE BUILDING PRIOR TO OCCUPANCY. <br />0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.