, . = REPAIR SPE�'ICATIONS AND LIST OP W0�0 HE SID <br /> Page 5 of 8 <br /> Address: 2310 Wetmoze <br /> 6. Electrical Replace the house main fuse panel and <br /> service wiring with a new recessed 200 amp breaker <br /> panel, G.E. oz equal, complete with service on same <br /> house wall with panel access in kitchen. Reconnect to <br /> existing underground wiring to garage noting garage has <br /> a freezer and lights along with receptacles. - <br /> Wire the entire house to code using existin9 lighting ' <br /> . and receptacle outlets where possible. in addition to <br /> receptacles added on the main floor, install 10 duplex <br /> receptacles in the attic rooms, 4 in the east bedcoom <br /> and the remaining 6 in the west room, evenly spread <br /> throughout areas. Contraator to note unfinished attic <br /> room will be sheetrocked and also a dcop ceiling will be <br /> installed over the bathroom and the entire kitchen <br /> acea. Wire in all kitchen and laundry appliances. See <br /> attached drawings. <br /> Light fixtures. Add 3 bedroom light fixtures in <br /> j upstairs, 2 in west room and 1 in the other room, all on <br /> • wall switches. Add light fixture over stairway on two <br /> . three-way wall switches. install 2 - 4 foot/2 tube <br /> florescent light panels to kitchen ceilinq in handy <br /> locations on two-three way wall switches. Add pull <br /> chain liqht under stairs. Add ceiling light fixture to <br /> main floor bedroom on wall switch. Add lighting to <br /> remaining rooms in house as required by code. install <br /> extecior light fixtuxes, one at the back and one at the <br /> - - �-��---Yrant—gaTch�atti on wall switches. Provide a total - <br /> lightinq fixture allowance of $250, owner to select <br /> fixtures. ' <br /> install a range hood (color to match owner's range) with <br /> • tvo-speed fan and work light and vent to house <br /> 'exterior. Provide and wire in two smoke detectors, one <br /> neac each sleeping area. - <br /> Heating. Install new electric baseboard heaters <br /> throughout the living areas of the house including the <br /> two attic rooms. Recessed el ctric wall heaters with <br /> fans are acceptable in the ki��chen and bathroom where <br /> . there may not � be enough wall space for baseboard <br /> heaters. All thermostats to be heater mounted. A1] new <br /> electric heaters shall be capable of maintainin9 a room <br /> temperature of 70° F. at a point three feet above the <br /> floor. <br /> All new electrical work shall be performed in comgliance <br /> Nith the requirements of the National Electrical Code, <br /> 1981 edition. <br /> s a 7CY� <br /> 7. Insulation Install R-11 batts to alf opened up wall <br /> cavi—'ties during the work called out in this spec. <br /> Install R-11 to open rafter spaces over sloping attic <br /> room and stairway. Install R-19 batts to short side <br /> walls of attic rooms. Add R-30 over horizontal ceiling <br /> in same attic room and R-30 to both horizontal ceiling <br /> areas on each side of attic room. Install R-30 to attic <br /> over bathroom. Install R-19 batt insulation between <br /> floor joists over house crawl space using metal rods or <br /> lath �for installation. <br /> Provide good air movement over all newly installed <br /> insulation, venting to code requirements. Vent czawl <br /> space to code. <br /> $ ��1 <br />