Laserfiche WebLink
• • • ,.}' \ \ <br /> �B�/� �O� <br /> March 9, 1999 <br /> Art Skotdal <br /> 2910 Colby Avenue <br /> Everett, WA 98201 <br /> Subject: Project: Snohomish Counry Surface Water Managernent <br /> Job Address: 2731 Wetmore Avenue <br /> Plan Check No.: C 61735 <br /> Dear Mr. Skotdal: <br /> In response to your application for a constructior. � , mit, your plans have been exa.�nined and you are <br /> advised that the issuance of a permit is being with,:eld for the reasons listed below. These comments <br /> address building issues only, additional revisions or additions may be required by other departments <br /> (such as Utilities, Planning ur Fire). All references refer to the 1997 U�iform Building Code, as <br /> amended by the State of Washington and/or Washington State Energy Code 1997 Edition, uNess stated <br /> otherwise. <br /> In order for the processin� of xour application to continue, it will be necessary to <br /> provide the Buildmg Divis�on w�th two complete new sets of drawings reflecting the <br /> corrections requested. <br /> I. i"he plans should be sealed by the architect of record. Section 1063.4 <br /> �r -l�e hc�✓ <br /> 2. A building data section should include the type of construction, existence of a monitored sprinkler <br /> and fire-alarm system, number of stories (building) and occupant load. <br /> �1.� Y� ��'�' <br /> 3. It should be clarified whether the existing and proposed ceilings aze part of the fire-resistive <br /> floodceiling assembly. Section 710.1 n� <br /> 4. The egress doors should swing in the direction of travel as the occupant load of the office space is <br /> greater than 50. This effects all doors into the corridor. Section 10033.1.5 <br /> 5. The double doors within the corridor should have doors that swing in opposite directions as they serve <br /> an occupant load greaier than 50. Note that each door must have a minimum nominal width of 36 <br /> inches. "I7ie doors by the elevator may not comply. Sections 1003.3.1.5 & 10033.1.3 �c�E d,,,7�,�. <br /> 6. The dead end hallway between the lunch room and toilet rooms should be revised to be less than 20 <br /> feet in length. Section 1004.2.6 .�x ,., „�� <br /> 7. It should be shown on the plans that the opening within the wall at the east end of the floor(i�etween <br /> the lunchroom and cubicles) is a minimiun of 32 inches clear to avoid dead end conditions. Section <br /> I]06.10.2 <br /> 3�; <br /> CITY OF EVERETT•3200 Cedar Sireet• Everett,WA 9?201 • (425)257-8C00 • Fax(425)257-8856 <br />