Laserfiche WebLink
. ! <br /> . • � �,. <br /> ;1an Check No. C 61735 <br /> March 9, 1999 I <br /> -' Page 2 of 2 <br /> � I <br /> i <br /> 8. Exit signs should be shown within the hallway to show the direction to the stai�s and on each side of <br /> the double doors. Section 1003.2.8.2 <br /> 9. The door within thc lunchroom should have 18" clear on the latch side(from the pull direc6on)W the � <br /> nearest obstruction. 1106.10.3 G,�is�� � <br /> 10.The reception counter should have a minimum 3' wide portion no higher than 3' above the floor. <br /> Section 1105.4.7.2 �,,�o,,c„�t� <br /> 11. Safety glazing should be shown for all glezing adjacent to doors where the nearest exposed edge of the <br /> glaudg is within a 24inch azc of either vertical edge of the dour in a ciosed position and wherr the <br /> bottom exposed edge of the glazing is less than 60 inches above the walking surface. Scetion 2406.4 <br /> Prepare a response letter showing whero each item in this cocrecdon letter is addressed on the plan set. <br /> Upon resubtnittal of the drawingc, youc applica:ion will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail a� contain sufficient informadon to ensure that t6e <br /> proposed savcture will be conswcted in compliaz�crwit6 all adopted codes. <br /> Sincerely, <br /> ��j�� <br /> To yd 'Lee <br /> Associate Engineer <br /> n:h+��.m�.o <br />