My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3229 WETMORE AVE 2018-01-02 MF Import
>
Address Records
>
WETMORE AVE
>
3229
>
3229 WETMORE AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2022 9:16:37 AM
Creation date
3/9/2017 1:48:27 PM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
3229
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
184
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c <br />Plan Check No. B 57335 <br />January 2, 1998 <br />Page 3 of 3 <br />i6. The siding shown within the stair enclosures should be specified to have a Class I Flame Spread <br />Classification per Table 8-A and Section 804.1. <br />Accessibility <br />I Details of the grab bars at the Type A unit bathtub should be provided. A grab bar is required on the <br />end wall over the drain, and 2 bars are required at the back wall. Section 1106.11.9.3 <br />2. The in -tub seat requirement per Section 1106.11.9.2 should be shown on the plans for the Type A <br />unit. <br />3. A shower spray unit, with a hose at leant 60 inches long, that can be used as a fixed shower head or <br />as a hand-held shower, shall be provided for the Type A unit. Section 1106.11.9.4 <br />Energy <br />�! It should be noted on the plans that all glazing shall be certified and labeled with its U-factor by an <br />independent agency licensed by the NFRC. Section 50:'..1.5.1 <br />.-22: JIt should be clarified how the additional R-8 insulation is to be achieved on the 2x4 construction per <br />the note on Sheet 15. Details should be provided where this occurs along with keying this <br />requirement to the plans or elevations. <br />Vapor retarders having a perm ratio of one or less should be shown installed on the warm side at all <br />walls and floors separating conditioned space from unconditioned space. Note that face stapling is <br />required for walls. Section 502.1.6 <br />Prepare a response letter showing where each item in this correction letter is addressed on the plan <br />set. <br />Upon resubmittal of the drawings, your application will be given priority and plan review will <br />recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to ensure that the <br />proposed structure will be constructed in compliance with all adopted codes. <br />Sincerely, <br />i <br />Tonyy Lee <br />Associate Engineer <br />
The URL can be used to link to this page
Your browser does not support the video tag.