My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3229 WETMORE AVE 2018-01-02 MF Import
>
Address Records
>
WETMORE AVE
>
3229
>
3229 WETMORE AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2022 9:16:37 AM
Creation date
3/9/2017 1:48:27 PM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
3229
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
184
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c <br />Plan Check No. B 57335 <br />January 2, 1998 <br />Page 2 of 3 <br />The exterior walls of this type V 1-hr building shall be a listed one -hour assembly. Currently, the <br />exterior side of the walls are shown unprotected per Section A/13. Table 5-A <br />The cripple wall shown in Section A/13 (and typical) should be shown bearing completely on the <br />concrete foundation wall below, or calculations provided which shows the capability of the plates to <br />resist the loads in compression perpendicular to grain, and any overturning loads induced due to the <br />eccentric loading. <br />Fire blocking should be shown in the I" air space at the floor to wall junction of Detail 12/14. <br />Section 708.2.1 <br />` The series of TJI should be specified for each intended size shown. <br />�/ 7� The stair landings and similar surfaces exposed to the weather should be waterproofed and sloped a <br />I/ minimum of/. unit vertical in 12 units horizontal (2% slope) for drainage. Section 1402.3 <br />Water-resistant gypsum sheathing should be specified f.,r the stair landings where one -hour fire - <br />protection is required. A weather resistive barrier should be installed over this GWB per Sections <br />1402.1 and 2511.1. <br />\ 1 9. A minimum of class C roof should be specified on the plans. Table 15-A <br />V <br />Exiting <br />�,V The stair rise (4 inches minimum, 7'/2 inches maximum) and run (10 inch minimum) should be <br />shown on Detail 1/11. Section 1006.3 <br />/2' All stair enclosure doors shall be specified to have a temperature rise not exceeding 450 degrees. <br />V/ Section 1009.3 <br />The ceiling of the stair enclosures is required to be a complete one -hour fire -resistive assembly, <br />otherwise the walls of the enclosures should continue to the underside of the roof sheathing. Section <br />711.2 <br />/A. The attic access hatch within the stair enclosures are not permitted and should be relocated to another <br />area. Section 1009.3 <br />L---S All openings in the exterior wall of the building which are within 10 feet of unprotected openings in <br />the interior stainvays should be protected with fire assemblies having a 45-minute rating. Thesc <br />assemblies should be fixed, self -closing, or automatic closing. Note that the garage door would also <br />have to comply with this requirement. Openings in the top floor are exempted. Section 1006.11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.