Laserfiche WebLink
16. <br />Exterior (court) walls within .................... feet of <br />lines should be of ...:............. hour construction. <br />Section .................... 03 (a). <br />17. <br />Openings in exterior (court) walls within ........... <br />feet of property lines should be protected with <br />three fourths hour fire assemblies. Section . <br />. <br />.................... 03 (b). <br />18, <br />Usable space under the first floor except in <br />Group I (J) Occupancies should be enclosed <br />as required in Section 1703. <br />19. <br />Fire -resistive construction for structural frame <br />elements in the exterior walls should comply <br />with Footnote No. 1 of Table No. 17-A and <br />Section ......................... See Section 1702 for <br />clarification. <br />20. <br />8uilding paper should be applied to exterior <br />walls as specified in Section 1707 (a). <br />21. <br />Enclosures for floor openings should comply <br />with Table No. 17•A. Section 1706. Details <br />should clearly indicate this. <br />22. <br />Structural members carrying masonry or eon. <br />crete walls in buildings over one story in height <br />should be protected with minimum one -hour <br />fire protection. Section 1708. <br />. <br />Nonabsorbent finish and backing, for toilet room <br />walls and floor should conform with Section <br />1711 (a). <br />24. <br />Shower stall walls should be finished with a <br />hard, nonabsorhent surface to a height of 6 <br />101 <br />feet. Section 1711 (b). <br />25. <br />Doors and panels of shower and bathtub en- <br />closure should comply with Section 1711 (e) <br />to (C)• <br />26.'iParapet <br />walls not less than ................ inches in <br />ieight are required. Section 1709. <br />h27. <br />Eave overhangs and similar architectural pro- <br />jections should comply with Section 1710. <br />p.......................................................................... <br />28. <br />Projections beyond the exterior wall should con- <br />form with the least restrdive of the following: <br />(a) A point one-third the distance to the proper. <br />ty line from an exterior wall. Section 504 <br />(b). <br />(b) A point one-third tf.e distance from an as- <br />sumed vertical plane located where fire' <br />resistive protection of openings is first re- <br />quired due to location of property. Section <br />504 (b). <br />29. <br />Envelope ceilings should satisfy the following <br />conditions [Section 4301 (b) 6.1: <br />(a) Should not be used to provide fire protec. <br />tion beam and Girders supporting more than <br />one floor. <br />(b) Columns should be Individually fire pro- <br />tected. <br />(c) Duct and outlet openings are limited to 100 <br />square inches in each 100 square feet of <br />[oiling area and should be protected with <br />approved fire dampers. <br />(d) Electrical outlet boxes should be of steel <br />and not greater than 16 square inches in <br />area. <br />30.E <br />Gypsum board ceilings in conjunction with fire - <br />resistive assemblies should be supported at <br />intervals not exceeding 16 inches. Itein 27, <br />Table No. 43-C. <br />31.' <br />wood stripping or suspended wood systems for <br />gypsum board ceilings should be not less than <br />2-inch nominal thickness. Section 4704 (b). . <br />[Section 4703 (b) for wall stripping.] <br />32. <br />Final partition layouts and details should be sub- <br />mitted prior to installation to justify compli- <br />ance with occupancy, fire -resistive, structural, <br />and exit requirements. <br />33. <br />Justifying test data in conformance with Section <br />106 or an ICRO research recommendation is <br />requiredfor ....................................................... <br />34. <br />Rooms in which rubbish (linen) chutes terminate <br />should be separated from the remainder of the <br />building with a one -hour occupancy separation. <br />Section 1705 (c). <br />35. <br />Openings into rubbish and linen chutes should <br />not be located in required exit corridors or <br />stairways. Section 1706 (c). <br />SPECIAL OCCUPANCY REQUIREMENTS <br />Group B <br />36. <br />R-3 Occupancies should be of one -hour fire. <br />resistive construction if located in a basement <br />or above.the first story. Section 702 (b). <br />37. <br />8.2 Occupancies with an occupant load of 1000 <br />or more should be in Type I, II, III one hour, III <br />Heavy Timber or IV one hour buildings. The <br />assembly room should not be in a basement <br />it it contains this high occupant load. Section <br />702 (b). <br />38. <br />The main entrance should front directly upon or <br />have'a 20-toot wide access to a public way at <br />least 20 feet in width. Section 703. <br />39. <br />Light and ventilation should comply With Section <br />705. <br />40. <br />A One Hour Fire Resistive Occupancy Separation <br />is required between the boiler or central heat. <br />ing plant and the rest of the building. Section <br />708. <br />41. <br />Lxtrrior openings for rooms containing a boiler <br />or central heating plant should be protected <br />with !hrce-fourths hour fire resistive assemblies <br />that art fixed, automatic, or self -closing if lo- <br />cated belc,v openings in another story or if less <br />than 10 feet from other doors or windows in <br />the same buPdi=g. Section 708. <br />Group C <br />42. <br />Atmospheric separations should comply with <br />Section 802 (b). <br />' <br />43. <br />Use of rooms should be clarified. Note that <br />rooms in Divisions 1 and 2 Occupancies used <br />for day care purposes and rooms used for <br />kindergarten, first, or second Dade pupils and <br />Division 3 Occupancies cannot be located <br />above the first story. Section 802 (c). <br />44. <br />Special hazard rooms should be separated from <br />other portions of the building by not less than <br />a One -Hour Fire -Resistive Occupancy separa• <br />lion. Section 802 (d). <br />45. <br />One required exit should front directly upon, or <br />have n 20-foot wide access to, a public way at <br />least 20 feet in width. Section 803 (a). <br />46. <br />Sanitary facilities should be provided in accord. <br />ance with Section 805. _ <br />47. <br />1 ighl and ventilation should comply with Section <br />80' <br />Sheet No. 2 of 6 Sheets <br />