Laserfiche WebLink
48. A One.Hour Fire Resistive occupancy Separation <br />Is required between the boiler or central heat. <br />ing plant and the rest of the building. Section <br />( 808. <br />1 r <br />Group O <br />49. <br />Group D, Division 1 Occupancies should be of <br />Type I or II construction unless complying with <br />the Exception in Section 902 (b). <br />50. <br />Group D, Division 2 (3) Occupancies should be <br />of one -hour fire resistive construction. Table <br />No. S.C. <br />51. <br />Light and ventilation should comply with Section <br />905. <br />52. <br />A One Hour Fire -Resistive Occupancy Separation <br />is required between the boiler or central heat- <br />ing plant and the rest of the building. Section <br />908. <br />53. <br />Exterior openings for rooms containing a boiler <br />or central heating plant should be protected <br />with three -fourths -hour fire -resistive assemblies <br />that are fixed, automatic, or self -closing if <br />located below openings in another story or if <br />less than 10 feet from other doors or windows <br />in the same building. Section 908. <br />Group r <br />54. <br />Motor vehicle service stations should be of non- <br />combustible fire retardant treated wood or one. <br />hour fire -resistive construction. Section 1102 <br />(b). <br />55. <br />Storage areas in excess of 1000 square feet in <br />connection with wholesale or retail sales should <br />be separated from the public areas by a One - <br />Hour Fire -Resistive Occupancy Separation un- <br />less the building is equipped throughout with <br />an automatic fire extinguishing system. Section <br />1102 (b). <br />56. <br />Light and ventilation should comply with Section <br />1105. <br />57. <br />Exhaust ventilation at or near floor level Is re- <br />quired by Section 1105. <br />58. <br />A One -Hour Fire Resistive Occupancy Separation <br />is required between a boiler room or central <br />heating plant and the rest of the building. Sec. <br />tion 1108. <br />Group H <br />59. <br />A Group 1' Occupancy more than two stories in <br />height or 4aving more than 3000 square feet <br />above the first story should be of one -hour <br />fire resistive construction throughout. Section <br />1302 (b). <br />60., <br />The following rooms should have window areas <br />as specified in Section 1305 (a), one-half of <br />which is openable. <br />.......................................................................... <br />.......................................................................... <br />61. <br />Mechanical ventilating system in bathrooms <br />should provide five air changes per hour di. <br />rectly to the outside Section 1305 (a). <br />62. <br />Windows from .......................................... should <br />not be considered as furnishing required light <br />or ventilation since they do not open to a yard, <br />court, or street in accordance with Section <br />1305 (a). <br />63. <br />Courts bounded on four sides with walls should <br />be at least 10 feet in length For courts more <br />than two stories in height, the required width <br />should be increased by one foot and the re- <br />quired length by 2 feet for each additional <br />story. Section 130G (e). <br />64. <br />Every sleeping room below the fourth floor <br />should have at least one window or exterior <br />door approved for emergency exit or rescue. <br />Section 1304. <br />65. <br />e <br />..:.:..... . '•. `I ::L6!: f.. ... room should <br />have the minimum ceiling height required <br />.m <br />Section 1307 (a). <br />66. <br />........................................................ room should <br />have a minimum superficial floor area of <br />.................... square feel. Section 1307 (b). <br />67. <br />Efficiency dwelling units should comply with <br />Section 1308. <br />68. <br />A One -Hour Fire Resistive Occupancy Separation <br />is required between a boiler room or central <br />heating plant and the rest of the building. <br />Section 1312. <br />69. <br />Every dwelling unit and guest room sho. nave <br />comfort heating facilities as specified in Sec- <br />tion 1311. <br />Group J <br />70. <br />Group J Division 1 Occupancies are limited to <br />1000 (3000) square feet in floor area and one <br />story in height. Section 1502. <br />71. <br />Garages should not open directly into a room <br />used for sleeping purposes. .Section 1504. <br />72. <br />An approved noncombustible material or asphal- <br />tic paving material is required for garage floor <br />surfaces. Section 1504. <br />EXIT REQUIREMENTS <br />73. <br />An occupant load sign is required in classrooms, <br />assembly areas, etc., having an occupant load <br />of more than 50. S^rtion 3301 (j). See ............ <br />.......................................................................... <br />74. <br />Conforming exits are required from the areas <br />below as specified in Section 33V (a). <br />.......................................................................... <br />.......................................................................... <br />75. <br />Exits should have a minimum separation of one- <br />half the maximum overall diagonal of the build• <br />ing or area served. Section 3302 (cj............... <br />76. <br />No point in the building should be more than <br />150 (200) feet from an exterior exit, horizontal <br />exit, enclosed stairway, or exit passageway, <br />measured in the direction of travel. Section <br />3302(d)........................................................... <br />77. <br />Exit door should swing in the direction of <br />egress. Section 3303 (b). See doors ................ <br />.......................................................................... <br />78. <br />Double acting doors are not allowed where, serv- <br />ing a tributary occupant load of more than 100. <br />Section 3303 (b). _ <br />19. <br />Exit doors should be openable from the inside <br />without the use of a key, special knowledge, or <br />effort. Section 3303 (c). Note also that flush <br />bolts or surface bolts are prohibited. <br />80. <br />Exit doors should be a minimum size of 3' x 6V <br />with a minimum door swing of 90 degrees. <br />Section 3303(d)............................................... <br />81. <br />The net dimension (clear width) at doorways <br />should be used in determining exit widths <br />required by Section 3302 (b). Sectio:r 3313 <br />(it). In consideration of door thicl.reesrCS, panic <br />hardware, door swing, etc., the required exit <br />widths (rave not bee" furnished. See door <br />