Laserfiche WebLink
Plan Check No. C-38681 <br />December 14, 1992 <br />Page Three of Four <br />22. Provide oudets per the National Electric Code. <br />23. Provide fan sizes, locadons and outdoor air inlets per V.I.A.Q. Code. <br />24. Vent dryers to exterior. <br />25. Indicate spacing of roof rafters and ceiling joists. <br />26. Provide attachment of roof �afters to ezisting framing. <br />27. Provide insulation baffles and one inch minimum air circulation space at eaves. <br />28. Set rafter eave blceking vertical and cut slope to under side of sheathing. Nail sheathing to <br />blocldng. <br />29. Provide mechanical attachment to 2x4 ceiling joists to 2x8 floor joists. Attachment cannot <br />depend on nails or screws subject to withdrawal (Note: this is not conventional conswction <br />and would not be required for fire ratings, sound control or other reasons and therefor, 2x4 <br />framing co�ld be omitted with ceiling attached to floor joists). <br />30. Provide foodngs for walls shown in Secdons E, F, and A. <br />All footings and foodng depth may be sized per Table 29-A. ' <br />31. Provide condnuous fire blocking within the floor joist space ahove the wall shown in Sxdon <br />A. <br />32. Footing drains should be placed at the bottom exterior side of all perimeter footings and tied <br />to storm sewer. <br />33. Slab edge insulation shall be placed on the ezterior vertical surface of the foundation wall. <br />34. The heat load calculations submitted are incorrect and do not meet the requiremems of the <br />W.S.E.C. <br />Please review the attached Energy Code infarmation and submit the appropriate form. <br />