Plan Check No. C-38681 <br />December 14, 1992 <br />Page Two of Four <br />9. A weather-resistive barrier must be applied to exterior walls as specified in Section 1708(a). <br />10. Anchored veneer must be attached in accordance with Section 3004(c) or by one of the <br />prescriptive methods set forth in Section 3006(d). <br />11. Water-resistant gypsum backing board shall not be used in the following locations (Section <br />4712): <br />a. Over a vapor retarder. <br />b. In areas sub�ect to continuous high humidity. <br />c, On ceilings. <br />I. GROUP R OCCUPANCY <br />12. Walls and floor separating dwelling units in the same building shall be of not less than 1-HR <br />fire-resisdve construcUon. Stction 1202(b). <br />13. � i� u� ���mmon by ce ants and�the �resti °flth�e buildi�ng. S Section 1202(bry rooms <br />14. EverX sleeping room below the fouRh story shall have at least one openable window or <br />extenor door conforming to Secdon 12az f�oree�me�Unrtcy escape or rescue, which must open <br />direcdy onto a public streEt or alley, y <br />15. Provide smoke detectors in each sleeping room and in the corridor outside sleeping areas per <br />Section 1210. <br />16. A 1-HR fire-resistive occupancy separation is required between z boiler room, central <br />heating plant, or hot water supply boiler and Group R, Division 1 Occupancies when serving <br />more than one dwelling unit. Secuon 1212. <br />17. Deck guardrail shall be constructed per Section 1712(a). <br />18. Deck stair shall be constructed per Section 3306. <br />19. Provide structural calculations to verify deck framing is capable of supporting dead and live <br />loads of structure (concrete topping slab) as shown. <br />20. Handgrip portion of stair handrail shall conform to Section 3306(i). <br />21. The window under the stair must be protected per Section 330ti(k). <br />