My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3710 WETMORE AVE 2016-01-01 MF Import
>
Address Records
>
WETMORE AVE
>
3710
>
3710 WETMORE AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2017 4:02:45 PM
Creation date
3/9/2017 2:10:05 PM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
3710
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plan Check No. C-38681 <br />December 14, 1992 <br />Page Two of Four <br />9. A weather-resistive barrier must be applied to exterior walls as specified in Section 1708(a). <br />10. Anchored veneer must be attached in accordance with Section 3004(c) or by one of the <br />prescriptive methods set forth in Section 3006(d). <br />11. Water-resistant gypsum backing board shall not be used in the following locations (Section <br />4712): <br />a. Over a vapor retarder. <br />b. In areas sub�ect to continuous high humidity. <br />c, On ceilings. <br />I. GROUP R OCCUPANCY <br />12. Walls and floor separating dwelling units in the same building shall be of not less than 1-HR <br />fire-resisdve construcUon. Stction 1202(b). <br />13. � i� u� ���mmon by ce ants and�the �resti °flth�e buildi�ng. S Section 1202(bry rooms <br />14. EverX sleeping room below the fouRh story shall have at least one openable window or <br />extenor door conforming to Secdon 12az f�oree�me�Unrtcy escape or rescue, which must open <br />direcdy onto a public streEt or alley, y <br />15. Provide smoke detectors in each sleeping room and in the corridor outside sleeping areas per <br />Section 1210. <br />16. A 1-HR fire-resistive occupancy separation is required between z boiler room, central <br />heating plant, or hot water supply boiler and Group R, Division 1 Occupancies when serving <br />more than one dwelling unit. Secuon 1212. <br />17. Deck guardrail shall be constructed per Section 1712(a). <br />18. Deck stair shall be constructed per Section 3306. <br />19. Provide structural calculations to verify deck framing is capable of supporting dead and live <br />loads of structure (concrete topping slab) as shown. <br />20. Handgrip portion of stair handrail shall conform to Section 3306(i). <br />21. The window under the stair must be protected per Section 330ti(k). <br />
The URL can be used to link to this page
Your browser does not support the video tag.