My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3726 WETMORE AVE 2016-01-01 MF Import
>
Address Records
>
WETMORE AVE
>
3726
>
3726 WETMORE AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2017 3:53:56 PM
Creation date
3/9/2017 2:13:04 PM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
3726
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
145
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f <br />I'lans for any such system shall be submitted to the Building DepaRment for examination and <br />approval. Such plans sl�all include plans for toe underground mains that will supply the sprinkler <br />system. <br />The type of sprinkler to be installed will be determined by the Building Official. It may be an NFPA <br />13, NFPA 13R, or NFPA 13D system depending upon several factors. Sprinkler installation shall <br />not begin without an approved and stamped set of plans trom the Buildiog Department. The <br />Pire Department will also review the plans and shall field inspect the installation based only on <br />approved plans that must be on site. Changes to plans must be approved by both the Building and <br />Pirc Departments. <br />Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br />Underground piping shall be hydrostatically tested and ilushed as established in NFPA Standazd 24 <br />for private fire mains. (Iiclow-eround nininP must be installed bv Washineton State Patrol <br />Licensed Undereround Snrinkler line certified "U" installers. For further infortnation, contact <br />the State Fire Marshal's O�ce at (360) 570-3134 or ccntact the Everett Fire Department at <br />(425) 257-8123.) All such tests shall be witnessed by a Pire Department inspcctor. Call (425) 257- <br />8124 to makc an appointmcnt for inspection. <br />Contractors' materials and test certificates shall be submitted to the Evereu �ire Department prior ro <br />issuancc of any Ccrti�icatcs of Occupancy. <br />Call (425) 257-8123 for morc inforniation. <br />9. Thrce Units or I,arcer - Sizc of tire sprinkler service and mctcr shall be calculated by a civil engincer <br />or fire sprinklcr designcr who is solcly responsiblc for this calculation. The City Public Works <br />Dcpartmcnt docs not rcvicw d�csc calcuiations anJ is not the authority having jurisdiction. All <br />buildings 3 units or larger that arc required to have a fire sprinkler must have a separate fire service. <br />Pire scrviccs largcr than 2" must conf'orni to City of Gvcrett Public Works Standard 515 and 523. <br />Thc fire sen�ice sidc of thc systcm must have a state-approvcd backflow prevention device. <br />10. Portablc Firc Protection - A portablc firc cxtinguishcr with a minimum U.L. rating of <br />2-A:10-f3:C shall bc providcd within 75 fcet of travel on all tloors of cach building during <br />construction and prior to occupancy. <br />1 L Por fire safcty in multi-fmnily projccts with community laundry facililics, the following is rcquired: <br />a. A sclf-closing, solid corc door shall be installcd for the laundry room. Any restraining device <br />shall be activated by an approvcd smoke dctector. <br />b. A covcred ntctal containcr shall bc provided for the disposal of combustiblc wastc in the <br />laundry room. <br />1?. Constivction and dcmolition of buildings shall be in compliance with the provisions of the 2003 <br />Imemational l�ire Cude, Chapter ld. <br />1 i, Pcmiits arc rcquired Gom thc Pirc Dcpartmcnt Cor removal nnd installation of underground fuel <br />ta:iks. <br />�✓ <br />
The URL can be used to link to this page
Your browser does not support the video tag.