2. Premise Idcntification - Premiscs shall be clearly identified by the correct address at the street entry. <br />Buildings shall be clearly identified so as to be visible and Iegible from the access road. Individual <br />apartments and suites, wherc applicable, shall be clearly and legibly identified from the acce�s road. <br />PREM[SE IDENTIFICATION AND ALL REQUIRED FIRE DEPARTMENT ACCESS <br />ROADS AND FIRE IiYDRANTS SHALL BE IN SERVICE PRIOR TO COMMENCEMENT <br />OF CONSTRUCTION. <br />4. Sccuritv Pence - Any security fence erected around the construction sitc shall br located so as to not <br />obstruct any existing hydrant, fire protection equipment, or Fire Department access. If Pire <br />Dcpartment acccss is obstructcd, gates or other openings shall be provided for access. <br />A fire hydrant is required within 200 driving fect, but not closer than 50 f'eet, of every structure. <br />Location of the hydrant(s) shall be approved by thc Firc Marshal. <br />C. Based upon 7,700 square fect of Type V-D, sprinklcred construction, the fire flow requirement is <br />I,500 gpm. <br />Fire Alarm Svstem - An approvcd automatic fire detection system shall bc provided as required by <br />City Ordinancc No. 1902-92, Chaptcr 16.76, of the Everctt Municipal Code. <br />Plans for such system shall be submittcd to the Pire Marshal for revicw and approval prior to <br />installation. Submittal shall include cut sheets of all cquipment intcnded for usc. Appropriatc trip <br />tests, witnesscd by a I�irc Dcpartment inspector, shall bc performed, along with a ccrtificate of <br />complclion, prior to tinal acccptance of the system. <br />Pirr, alann systcros shall bc installcd according to NFPA Standard 72. Installation of firc alarm <br />ce�mponcnts, including basic wiring, may not commence before plans are approved by the Fire <br />I)epartment Plan Revicwer. Pirc alarni drawings must be professionally rendered, in sufficient <br />dctail, and must bc intcmally consistcnt. ftiscr diagrams must match installation plans and load <br />calculations. Components must be listed and approved for use togethec Changes to plans must <br />includc new drawings and calculations and must bc approved by the Pire Departmcnt Plan Revicwer <br />prior to installation. I�irc alarm installation is subjcct to field inspcction by a I'irc Ucpartmcnt <br />II15�CClOi. All :l�rlOVl'(I SCl O� rlans and the [3uilding llepartme�u electrical pemiit must bc present <br />ti�r any installatiun inspcction. <br />Piro alami systcros shall bc installcd undcr pemiit of lhc City of Gvcrclt Duilding Department. <br />I�Icctrical inspcetions mid approval arc requircd prior to calling for acccptancc tcsts. Call (425) 257- <br />3810 lor permit infonnation. <br />Thc :�bscnce of ��•orking phonc lines fur the alarm system will bc causc for postponing fire <br />Jepartment inspecliun and tcsting and shall result in denial of occupancy. <br />Pire Sunnression ISprinklerl Svstcm - An approved automatic suppression system shall be provided <br />as rcquircd by City Ordinancc No. 1902-92, Ch�ptcr 16JG, of thc Evcrctt Municipal Codc. Thc <br />s� stcm must includc :i mcch.�nicul watcr gang bcll. <br />D� <br />