My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3827 WETMORE AVE 2016-01-01 MF Import
>
Address Records
>
WETMORE AVE
>
3827
>
3827 WETMORE AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2017 3:33:51 PM
Creation date
3/9/2017 2:18:17 PM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
3827
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plan Check No. 91/26812 <br />Page Two of Three <br />5. Habitable space shall have a ceiling height of not less than 7 feet 6 <br />inches, except as otherwise permitted in Section 1207 UBC. <br />Kitchens, halls, bathrooms and toilet compartments may have a ceiling <br />height of not less than 7 feet measured to this lowest projection <br />from the ceiling. <br />If any room in a building has a sloping ceiling, the prescribed <br />ceiling height for the room is required in only one half the area <br />thereof. No portion of the room measuring less than 5 feet from the <br />finished floor to the finished ceiling shall be included in any <br />computation of the minimum area thereof. <br />The bedroom does not provide the minimum required ceiling height in <br />at least one half of the room. <br />6. Each water closet r.aol shall be located in a clear apace not Less <br />than 30 inchet Ln ".dth and have a clear space in front of the water <br />closet etool of not laea then 24 inchea. <br />7. All 125 volt, single phase 15 and 20 ampere receptacles installed in <br />kitchens in a dwelling unit on the small appliance branch cizcuits, <br />except for thoae receptacle outlets for dedicated use, 'such as for a <br />diahwasher, disposal, trash compactor, refrigerator or freezer. <br />shall have ground-fault circuit•interrupter protection for personnel. <br />8. Receptacle outlets shall be installed so that no poin� along the <br />floor line in any wall space is more than 6 feet, measured <br />horizontally, from an outlet in [hat space, including any wall. space <br />2 feet or more in vidth. <br />9. 2x6 deck joists are overstressed. Provide new design for deck <br />10. 4x6 beam supporting deck joists is overstressed. Provide new beam <br />size, species a�d grade. <br />11. Provide detail showing how 1-hour separation betr;een dwelling units <br />is achieved. Tha asaembly detailed must have been tested by an <br />approved testing laboratory or provide test results for the proposed <br />assembly. <br />12. Drawings do not refle•t actual condi�ions of structure as it is <br />conatructed. Orawings shall reflect actual conditions. <br />
The URL can be used to link to this page
Your browser does not support the video tag.