Laserfiche WebLink
Plan Check No.; 92/35731 <br />March 24, 1992 <br />Page 1wo of Four <br />2. The guerdrail above the stair must be 36" high minimum ei3 � <br />must be constructed so a 6" sphere cannot pass thru the rail. <br />Please provide a construction detail. s��c R��H��W r'4� Z <br />3. Clarify foundation steps and height of edjacent grade. <br />U�supported faundation wells (top of val: is not at the floor <br />line) over 4'-0" hlgh must be designed by a licensed <br />strucLural engineer. SE� q-rTAc�{�,� �- � 3 j p,�,q�,�G. <br />4. Footings must be located 1'-6" minimum below the adjacent <br />grade. S�� ATT/7CrMiCrtl7' �{ / <br />5. The roof framing may be overstressed. I auggest using one of <br />the following options from tables 25-A.1 and 25-U-R-B of the <br />1988 UBC. / <br />Hem Flr No,_1_2X8 j,d " o.c. <br />"tlemFir2lo. 2 2x8 @ 12_o.c // <br />Flem E`�r No, 2`2�q10 @ 24" o,c. <br />Douglas Fir-Larch No. 2 2x8 @ 16" o.c. <br />Douglas Fir-Iarch No, 2 2x10 @ 24" o.c. <br />6. Please indicate the connection�of [he new roof framing to the <br />existi roof framing. O PE AJ E Y, I ST/Nb �p oo r- ��c16 %�I�10 <br />Gnn►ti`�c T To <br />7. The energy code form submitted is out of date and as oF <br />Jan�ary 1, 1992 the City of Everett has adopted the Washington <br />State Enr_rgy Code and Ventilation and Indoor Air Quality Code. <br />