Laserfiche WebLink
PUBL/C N/O � <br />May 3, 1995 <br />Dave Hanson <br />1054 N Park Drive <br />Everett WA 98203 <br />RE; Owner: Mike Smith <br />Job Address: 4809 Willmington <br />plan Check /l 48193 <br />Deax Mr. Hanum: <br />In response to your application for a construction permit, your plans have been <br />exainined and you aze advised that the issuance of a permit is being withheld for the <br />reasons listed below. These comments address building issues only, additional <br />revisions or addidons may be required by other departments (such as Utilities, Planning <br />or Fire). All references refer to the 1991 Uniform Building Code, as amended by the <br />Stace of Washington and /or Washington State Energy Code 1994, lst Edidon, unless <br />scated otherwise• <br />1 getow grade walls are required to be insulated to min. R-19 on the interior or <br />min. R-10 on the ezterior. <br />2. Show on plans which walls ue existing and which walls aze proposed• Also <br />show any walls to be removed (if applicable). <br />Rll <br />4. <br />All g�est rooms and habitable rooms within a dwenings with anlareap ot less <br />with natural light by means of exterior glazed oPe B <br />than one tenth of the floor azea of such rooms with a min. of 10 square feet. <br />The "activity room" has no windows. <br />All guest rooms and habitable rooms within a dwelling unit shall be provided <br />with natural ventilation by means of openable exterior openings with an azea not <br />less than one twentieth of the floor azea of such rooms with a min. of S sq. ft. <br />CITY OF EVERETT• 3200 Cedar Street • Everett. WA 982oi '(206) 259•8800 • Fax (206) 259-8856 <br />