Laserfiche WebLink
r <br /> � PJU �'/C I�t/O/� � <br /> June 5, 1996 <br /> A� ��� o � � r� ad � D <br /> 1815 19th Drive � � <br /> — Mutaiceo, wn 9s2�s �Uf� i i 1996 <br /> , Subject: Owner: AlOstman ..._... ..........................._............ <br /> Job Address: 1622 Silver Lake Road B�� pe�ml�Coun eT <br /> Plan Chxk No: 51650 <br /> Dear Mr. Ostman: <br /> In response to your a�plication for a construction permit, your plans have been ezaminad and you <br /> are adv�sed that the issuance of a permit is being withheld for the reasons listod below. T7►ese <br /> comments address building issues only, additional revisions or additions may be requirod by other <br /> deparcments (such as Util�hes, Planning or Fire). All references refer W the 1994 Umfotm <br /> Building Code, as amended by the State of Washington and/or Washington State Energy Code <br /> 1995 Edidon, unless stated otherwise. <br /> In order for the processing�of your application to continue, it will be necessary <br /> to provide the Building Division w�th two complete new sets of dritwings <br /> reflecting the corrections requested. <br /> 1. Plans as submitted do not meet the prescriptive requirements for lateral bracing per <br /> � � \�. Section 2326.4.1, 2326.1 l.t and Table 23-I-W. All braced wall panels shall be cleady <br /> indicated on the plans. <br /> The plans as submitted constitute on unusually shapad building. When of unusual stiape, <br /> buildmgs of light-frame construction shall have a lateral-force-resisting system designe� <br /> to resist the forces specified in Chapter 16 UBC/2326.4.4 UBC. <br /> 2. Specify on the plans that exterior joints shall be sealed, caulked, gasketed, or weather- <br /> �)� stripped to limit air leakage at the following locations: 502.4.3 <br /> a. windows and door frames <br /> b. openings between walls and foundation <br /> c. between walls and roof <br /> d. openings at penetration of utility services <br /> e. all other opemngs in the builJing envelope <br /> ,., 3. Note on the plans that a11 heating ducts in unconditioned spacxs are to be insulated to a <br /> (� '> minimum of'R-8. All ductwork seam joints are to be taped and sealed and fastened with <br /> \� a minimum of the fasteners. .503.10 <br /> �� ; 4. Specify on plans that non-recirculating hot and wld water pipes located in unconditioned <br /> space shall be insula�ed to R-3 minimum. 503.11 <br /> CITY OF EVERETT•3200 Cedar Sireet• Everett,WA 98201 • (206) 259-8800• Fax(206)259-8856 <br />