My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1622 SILVER LAKE RD 2016-01-01 MF Import
>
Address Records
>
SILVER LAKE RD
>
1622
>
1622 SILVER LAKE RD 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2017 8:35:24 PM
Creation date
3/9/2017 8:35:16 PM
Metadata
Fields
Template:
Address Document
Street Name
SILVER LAKE RD
Street Number
1622
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. <br /> i �" � <br /> Plan Check No. 51650 <br /> June 5, 1996 <br /> Page 2 of 2 <br /> 5. Soura speci6c fans ace required in each Idtchen, bathraom, wa0er closet, laundry <br /> facility, mdoor swimmingpoo l, spa, and other rooms wha+e exass wata vapor or <br /> � �3 000ldng odor is produoed. Specify the fan la�adons and sius at minimum of SO CFM at <br /> 0.25" w�ata gauge for bathrooms and laundries and 100 CFM at 0.25" for Icitchena. <br /> 6. Specify on the plans which whole house vendlation system is used, sin le . <br /> p � , bined soura spxific fans for whole houx exhaust mte�ahon vn <br /> f��,� forced-air systems or dedicated heat reco�ery vendla6on system. <br /> NoibV• <br /> 7. The whole housc system must be ca�able of providing at least 0.35 sir changes pa hour <br /> �,�� but not less than 15 cubic feet per mu�ute. Indicate the minimum CFM of the sysOan an <br /> the plans. <br /> 8. Outdoor air is required to be suppliea ro all habitable moms for all wholo-houx <br /> ventiladon systems. Specify the rype of outdoor air system including individual ouWoor <br /> ��3 sir inlets, forced-air heating system, ducting or equivalent means. <br /> 9. Note un the plans that outdoor air inlets shall not be placed in the following locadons: <br /> a. closer than 10' from an appliance vent outlet, unless such va►t outlet is 3" above the <br /> �� i outdoor air inlet <br /> ' b. where it will pick up objecdonable odors, fumes or flammable vapors <br /> c. a hazardous or unsan�tary location <br /> d. a room or space having any fuel-burning appliances <br /> 10. Note on the drawings that all swctural panel �mponents of the house such as softwood, <br /> ,� �(' plywood, particle board, wafer board and orientad strand board shall be identified as <br /> "EXPOSURE 1", "EX1'ER10R" or "HUD-APPROVED". 400.1 <br /> •� . 11. Spiral stairways shall comply with SecGon 1006.6 of the UBC. Show requiremencs on <br /> � ' plans. <br /> Prepare a rcsponse letter showing where each item in this correction letter is addrossed on the plan <br /> set. <br /> Upon msubmi►tal of the drawings, your application will be given prioriry and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient informadon to ensure that <br /> the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> ��� <br /> eff Heilman <br /> Development Technician <br /> ,x:wnrwr.+.ii <br />
The URL can be used to link to this page
Your browser does not support the video tag.