" � <br /> �� <br /> Jeff McFall <br /> March 1,2000 <br /> Page 1 of 5 <br /> Exiting <br /> 1. When a required exit enters the atrium space,the travel distance from the doonvay of the tenant <br /> space to a horizontal exit or stair enclosure should not exceed 100 feet. Section 402.5.1 <br /> 2. A horizontal exit may not be locked from within the atrium (the expansion spaces). An exit <br /> diagram should be shown on thr plans which cls�fies the horizontal exits on the second and <br /> third floors — note that exit signage may need to be revised upon further review. Section <br /> 10053.5 <br /> 3. Each pair of doors serving as a horizontal exit have the leaves swinging in opposite direction <br /> as the nccupant load served is greater than 50 from each side. Section 1Q033.1.5 <br /> 4. Class I standpipes are required for this building. They should be shown at each required <br /> stairway and horizontal exit as specified in Section 904.53 <br /> 5. 'fhe horizontal exits established on the second and third floors do not effect the atrium walls on <br /> the first floor as two-hour floor/ceiling assemblies are used. The walls may then be of <br /> minimum one-hour fire-resistive conswction (per nom�al Type II- F.R. req.'s.) with opening <br /> protection only as required by Section 4023 (atria?. Sections 302.2& 10053.5.2 <br /> 6. Corridor doors should be specified to have an 'S' rating on the label. Section 1004.3.4.3.2.1 <br /> 7. 7he elevators opening into rated c.urridors should be shown with lobbies. Section 1004.3.4.5 <br /> 8. Doots into stair enclosures and horizontal exits should be specified to have a maximum <br /> temperative rise of 450 degrees. Sections 1005.3.3.5 8c 1005.3.5.3 <br /> Accesaibility <br /> 1. The parking stalls in tfie South Pazking Lot should be shown with curb cuts at the access aisles. <br /> Section 1106.4.7 <br /> 2. The code infortnation section on the cover sheet should state that quick-response sprinklers are <br /> being used in lieu of azeas of evacuation assistance. The written fire-and life-safety emergency <br /> evacuation plan should be submitted for co-review (to include the fire chie�. Please note that <br /> the plan should also specifically address the secund floor bridge at Stair !�1 where steps are <br /> located within a mquired means of egress. Section l 104.1 � <br /> 3. Glazing in doors should be sho�vn no higher than 43"above the floor. Section 1106.10.7 <br /> 4. The door to the ambulatory toilet stall (women's bathroom, first floor) should swing outwazd. <br /> Section 1106.11.4 <br />