Laserfiche WebLink
Melvin Boggess <br />Jufy 15, 2003 <br />Plan Check No. C0307-008 <br />Page 2 of 2 <br />�. <br />6. Windows located within 24" of either edge of a door in the closed position are <br />reyuired to be safety glass. Show on plans. <br />7. All habitable rooms are required to have natural li�ht and ventilation by means of <br />exterior �lazed openings. Provide minimum 1/10 of floor area for natural light <br />and 1/20 of floor area for ventilation. <br />8. Incorporate engineering requitements intc construction drawings. Show which <br />option you will use. <br />9. The closet addition in the bedroom adjacent to the living room may encroach into <br />the required minimum width for the toilet. Show actual dimensions of closet and <br />show minimum cleazance of the toilet. <br />Prepane a response letter showing where each item in this correction letter is addressed on the <br />plan set. <br />Upon resubmittal of the drawings, your application will be given priority and pian review will <br />recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to ensure <br />that the proposed structure will be constructed in compliance with all adopted codes. <br />Sincerely, <br />���d,�-- <br />Jeff Heilman <br />Development Tcchnician <br />S:VLindsarU\'ORDViHILMAN, N'lan Check #C0307-OOR.doc <br />