' �[ '<� <br /> controls, receptacles or dispensers are no higher than 40"A.F.F. - see sheet A6.0. <br /> Section 1105.2.3 <br /> BN&H: Addendum No. 2, dated May 20, 2003, clarifies these requirements by added <br /> General Notes # 9 and 10 on drawinc� sheets A6.0, A6.1 and A6.2. <br /> 2. Hot water and drainpipes exposed under the lavatories should be shown guarded or <br /> wrapped to prevent contact. Section 1106.11.7.4 <br /> BN&H: Addendum No. 2, dated May 20, 2003, clarifies these requirements by added <br /> General Note#2 on drawing sheets A6.0, A6.1 and A6.2. <br /> 3. Tlie clearances in the accessible toilet stalls should be dimensioned on the plans. <br /> Section 1106.11.5.2 <br /> BN&H: Addendum No. 2, dated May 20, 2003, clarifies these requirements by added <br /> General Notes #6 and 7 on drawing sheets A6.0, A6.1 and A6.2. Dirt�ensions <br /> shown on drawing shee�s A6.0, A6.1 and A6.2 provide for those clearance <br /> requirements. <br /> 4. The top of the seat of the accessible water closets should be shown between 1 i"-19" <br /> A.F.F. Section 1106.11.5.2 <br /> BN&H: Addendum No. 2, dated May 20, 2003, clarifies this requirement by added <br /> General Note# 3 on drawing sheets A6.0, A6.1 and A6.2. <br /> 5. The flush controls of the accessible water closets should be shown on lhe wide side of <br /> the toilet stail - See elevation 5/A6.0 (and typ.) Section 1106.11.5.4 <br /> BN&H: Addendum No. 2, dated May 20, 2003, clarifies this requirement by added <br /> General Note#4 on drawing sheets A6.0, A6.1 and A6.2. <br /> 6. When urinals are provided, at least one should comply with the following as specified in <br /> Section 1106.11.6 (Section 1105.2.2): <br /> a. The side shields may project no farther than the front edge of the urinal rim. <br /> b. The urinai should have an elongated rim, at a maximum of 17 inches above the <br /> floor. <br /> c. Flush controls must be mounted not more than 44" A.F.F. <br /> BN&H: Addendum No. 2, dated May 20, 2003, clarifies these requirements by added <br /> General Note # 1 on drawing sheets A6.0, A6.1 and A6.2. <br /> 7. The minimum 36" width of the ambulatory accessible toilet stalls should be dimensioned <br /> on the plans. The door should be specified to be seif-closing. Section 1106.11.4 <br /> BN&H: Addendum No. 2, dated May 20, 2003, ciarifies these requirements by added <br /> General Notes # 5 8 7 on drawing sheets A6.0, A6.1 and A6.2. <br /> 8. The pians should show the accessible lavatories (minimum of one per toilet room) have <br /> a knee clearance of not less than 27 inches in height, 30 inches in width and 17 inches <br /> in depth. Section 1106.11.7.3.1 <br /> BN&H: Addendum No. 2, dated May 20, 2003, clarifies these requirements by added <br /> General Note # 8 on drawing sheets A6.0, A6.1 and A6.2. Confirming <br /> dimensions are shown on those drawiny sheets. <br /> 9. Water fountains should be detailed so that compliance with Section 1106.13 may be <br /> verified. <br /> =l�P <br />