My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 HEWITT AVE EVERETT EVENT CENTER 2016-01-01 MF Import
>
Address Records
>
HEWITT AVE
>
2000
>
EVERETT EVENT CENTER
>
2000 HEWITT AVE EVERETT EVENT CENTER 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2017 2:11:53 PM
Creation date
3/16/2017 8:00:07 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2000
Tenant Name
EVERETT EVENT CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
319
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' �[ '<� <br /> controls, receptacles or dispensers are no higher than 40"A.F.F. - see sheet A6.0. <br /> Section 1105.2.3 <br /> BN&H: Addendum No. 2, dated May 20, 2003, clarifies these requirements by added <br /> General Notes # 9 and 10 on drawinc� sheets A6.0, A6.1 and A6.2. <br /> 2. Hot water and drainpipes exposed under the lavatories should be shown guarded or <br /> wrapped to prevent contact. Section 1106.11.7.4 <br /> BN&H: Addendum No. 2, dated May 20, 2003, clarifies these requirements by added <br /> General Note#2 on drawing sheets A6.0, A6.1 and A6.2. <br /> 3. Tlie clearances in the accessible toilet stalls should be dimensioned on the plans. <br /> Section 1106.11.5.2 <br /> BN&H: Addendum No. 2, dated May 20, 2003, clarifies these requirements by added <br /> General Notes #6 and 7 on drawing sheets A6.0, A6.1 and A6.2. Dirt�ensions <br /> shown on drawing shee�s A6.0, A6.1 and A6.2 provide for those clearance <br /> requirements. <br /> 4. The top of the seat of the accessible water closets should be shown between 1 i"-19" <br /> A.F.F. Section 1106.11.5.2 <br /> BN&H: Addendum No. 2, dated May 20, 2003, clarifies this requirement by added <br /> General Note# 3 on drawing sheets A6.0, A6.1 and A6.2. <br /> 5. The flush controls of the accessible water closets should be shown on lhe wide side of <br /> the toilet stail - See elevation 5/A6.0 (and typ.) Section 1106.11.5.4 <br /> BN&H: Addendum No. 2, dated May 20, 2003, clarifies this requirement by added <br /> General Note#4 on drawing sheets A6.0, A6.1 and A6.2. <br /> 6. When urinals are provided, at least one should comply with the following as specified in <br /> Section 1106.11.6 (Section 1105.2.2): <br /> a. The side shields may project no farther than the front edge of the urinal rim. <br /> b. The urinai should have an elongated rim, at a maximum of 17 inches above the <br /> floor. <br /> c. Flush controls must be mounted not more than 44" A.F.F. <br /> BN&H: Addendum No. 2, dated May 20, 2003, clarifies these requirements by added <br /> General Note # 1 on drawing sheets A6.0, A6.1 and A6.2. <br /> 7. The minimum 36" width of the ambulatory accessible toilet stalls should be dimensioned <br /> on the plans. The door should be specified to be seif-closing. Section 1106.11.4 <br /> BN&H: Addendum No. 2, dated May 20, 2003, ciarifies these requirements by added <br /> General Notes # 5 8 7 on drawing sheets A6.0, A6.1 and A6.2. <br /> 8. The pians should show the accessible lavatories (minimum of one per toilet room) have <br /> a knee clearance of not less than 27 inches in height, 30 inches in width and 17 inches <br /> in depth. Section 1106.11.7.3.1 <br /> BN&H: Addendum No. 2, dated May 20, 2003, clarifies these requirements by added <br /> General Note # 8 on drawing sheets A6.0, A6.1 and A6.2. Confirming <br /> dimensions are shown on those drawiny sheets. <br /> 9. Water fountains should be detailed so that compliance with Section 1106.13 may be <br /> verified. <br /> =l�P <br />
The URL can be used to link to this page
Your browser does not support the video tag.