� � <br /> BNBH: Addendum No. 2, dated May 20, 2003, revised drawing sheet A10.0 Room <br /> Finish and Door Scheduies to add a new Keynote #22.0 Provide Panic <br /> Hardware, per Hardware Schedule; and to add that Keynote to the "Remarks" <br /> column for the doors where that is a requirement. <br /> 5. Doors M05C shouid be shown with panic hardware. Section 1007.2.5 <br /> BN&H: As indicated in response to Exiting Item #3, above, Addendum No. 4, dated <br /> June 3, 2003, deleted door M05C. <br /> 6. Door 101A has been mislabeled in the hardware schedule as Door 001A. <br /> BNBH: Addendum No. 1, dated May 12, 2003, revised the door number on the <br /> Hardware Scheduie to the correct 101A. <br /> 7. Tne room capacity signs (for posting) should be shown on the plans for meeting rooms <br /> 2 & 3. Section 1007.2.6 <br /> BN&H: As indicated in response to Exiting Item #3, above, Addendum No. 4, dated <br /> June 3, 2003, revised drawing sheet AA1.1 Meuanine Level Floor Plan to <br /> provide wal!-moun'.ed maximum occupancy signase in those rooms. <br /> 8. The ballroom has the capability of being divided into four smaller meeting rooms. Each <br /> smaller room should have its maximum occupancy posted. Section 1007.2.6 <br /> BN&H: Addendum No. 2, dated May20, 2003, revised drawing sheet A1.2 Second <br /> Level Floor Plan to provide separate wall-mounted maximum occupancy <br /> signage for the whole un-divided space and for the four smaller subdivided <br /> spaces. <br /> 9. Doors 222A, 222B, 219D, 220A 8 2208 should be listed in the door schedule. <br /> BN&H: Addendum No. 1, dated May 12, 2003, replaced drawing sheet A70.0 Room <br /> Finish and Door Schedules. The replacement sheet A10.0 lists those doors. <br /> 10.All corridor doors should be shown as having "S" labels. Section 1004.3.4.3.2.1 <br /> BN&H: Addendum No. 2, dated May 20, 2003, revised drawing sheet A10.0 Room <br /> Finish and Door Schedules to add a new Keynote #23.0 Provide "S" Label; and <br /> to add that Keynote to the "Fire Rating Labei" column for the doors where that <br /> is a requirement. <br /> 11. Exit signs should be provided at doors 101A, each side of doors M05C, and on the east <br /> side of doors 202C 8 202D. Section 1003.2.8.2 <br /> BN&H: Addendum No. 2, dated May 20, 2003, revised drawing sheets E1.1 and E1.3, <br /> with drawinos SKE1.1 and SKE1.3 to provide exit light fixtures at doors 101A, <br /> 202C and 202D. As indicated in response to Exiting item #3, a5ove, <br /> Addendum No. 4, dated June 3, 2003, deleted door M05C. <br /> Accessibility <br /> 1. When the following fixtures are provided, at least one 'set' should comply with the <br /> following requirements of Section 1106.11.8: mirrors and shelves in toilet rooms must be <br /> mounted such that the bottom of the mirror(or top of shelf) is within 40 inches of the <br /> floor. Dr :ng equipment, towel of other dispensers must be mounted such that the <br /> a�� <br />