My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 HEWITT AVE EVERETT EVENT CENTER 2016-01-01 MF Import
>
Address Records
>
HEWITT AVE
>
2000
>
EVERETT EVENT CENTER
>
2000 HEWITT AVE EVERETT EVENT CENTER 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2017 2:11:53 PM
Creation date
3/16/2017 8:00:07 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2000
Tenant Name
EVERETT EVENT CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
319
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � t t. <br /> Ltr. Deric Von Schlieder <br /> May 14, 2003 <br /> Page 4 <br /> 2. Hot water and drainpipes exposed under the lavatories should be shown guarded or wrapped <br /> to prevcnt contact. Section 1106.11.7.4 <br /> 3. The clearances in the accessible toilet stalls should be dimensioned on the plans. Section <br /> 1106.11.4.1 <br /> 4. The top of the seat of the accessible water closets should be shown between 1?"-19" A.F.F. <br /> 5ection 1106.11.5.2 <br /> 5. The flush controls of the accessible water closets should be shown on the wide side of the <br /> toilei stall —See elevation 5/A6.0 (and typ). Section 1106.11.5.4 <br /> 6. When urinals are provided, at least one should comply with the following as specified in <br /> Section 1106.11.6 (Section 1105.2.2): <br /> a. The side shields may project no farther than the front edge of the urinal rim. <br /> b. The urinal should have an elongated rim, at a maximum of 17 inches above the floor. <br /> c. Flush controls must be mounted not more than 44" A.F.F. <br /> i. 'Ihe minimum 36" width of the ambulatory accessible toiiet stalls shouid be dimensioned on <br /> the plans. The door should be specified to be self-closing. Section 1106.11.4 <br /> 8. The plans should show the accessible lavatories (minimum of one per toilet room) have a <br /> knee clearance of not less than 27 inches in height, 30 inches in width and 17 inches in <br /> depth. 5ection 1106.11.7.3.1 <br /> 9. Water fountains should be detailed to that compliance with Section 1106.13 may be verified. <br /> Section 1105.4.1 <br /> Please prepare a response letter showing where each item in this correction letter is addressed on the <br /> plan set. <br /> Upon resubmission of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure that <br /> the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> � _— � . <br /> .�a,.,� .� _ __ • <br /> � <br /> Tony R. Lec <br /> Plans Examiner �,/ <br /> / <br />
The URL can be used to link to this page
Your browser does not support the video tag.