My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 HEWITT AVE EVERETT EVENT CENTER 2016-01-01 MF Import
>
Address Records
>
HEWITT AVE
>
2000
>
EVERETT EVENT CENTER
>
2000 HEWITT AVE EVERETT EVENT CENTER 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2017 2:11:53 PM
Creation date
3/16/2017 8:00:07 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2000
Tenant Name
EVERETT EVENT CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
319
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. � � <br /> Ltr. Deric Von Schlieder <br /> May 14, 2003 <br /> Paee 3 <br /> Exiting <br /> 1. It has bcen determined that the four doors from the arena (horizontal exit) on the second <br /> level do not servc an occupant load of 50 or more from the "city building" side (Door 202A <br /> is less than 20' Crom the main corridor) and therefore a dead-end condition dces not exist. <br /> Door 216A may be removed. Section 1004.2.6 <br /> 2. Corridors 012 & 219 are not required to be rated comdors. They may be changed to <br /> hallways. Section 1004.2.2 <br /> 3. The exit access doors from meeting rooms 2 & 3 into corridor M14 should be separated <br /> from each other by a minimum of '/: the diagonal of the combined rooms (MOS & M06) as <br /> they share a required 2"`�exit. Section 1004.2.4 <br /> 4. Doors requiring panic hardware should be so specified on the door schedule. Section <br /> 1007.2.5 <br /> 5. Doors ivI05C shuuld be shown wilh punic hardw:ue. Secliuu 1007.2.5 <br /> 6. Door IOIA has been mislabeled in [he hardware schedule as Doar 001 A. <br /> 7. The room capacily signs (for posting) should be show�n on the plans for meeting rooms 2 & <br /> 3. Section 1007.2.6 <br /> 8. The ballroom has the capability of being divided into four smaller meeting rooms. Each <br /> smaller room sliould have its maximum occupancy posted. Section 1007.2.6 <br /> 9. Doors 222A, 222B, 219D, 220A & 220B should be lisred in the door schedule. <br /> 10. All corridor doors should be shown as having `S' labels. Section 10043.4.3.2.1 <br /> l I. Lxit signs should be provided at doors IOIA, each side of doors MOSC, and on the East side <br /> of doors 202C & 202D. Section 1003.2.8.2 <br /> :lccessibility <br /> L When the following fixtures are provided, at least one 'set' should comply with the <br /> following requirements of Section 1106.11.8: mirrors and shelves in the toilet rooms must <br /> be mounted such that the bottom of the mirror (or top of shelfl is within 40 inches of the <br /> Floor. Drying equipment, towel or other dispensers must be mounted such that the controls, <br /> receptacles or dispensers are no higher than 40" A.F.F—see sheet A6.0. Section 1105.23 <br /> �l� <br />
The URL can be used to link to this page
Your browser does not support the video tag.