My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1318 37TH ST 2018-01-02 MF Import
>
Address Records
>
37TH ST
>
1318
>
1318 37TH ST 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2021 11:06:08 AM
Creation date
3/31/2017 9:47:55 AM
Metadata
Fields
Template:
Address Document
Street Name
37TH ST
Street Number
1318
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
797
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plan Check Review Nos. B59674, B59674, B59676 <br />October 13, 1998 <br />Page 9 of 9 <br />i <br />( . The location and details of the required "whole house fan" should be on the plans. Section 304, <br />Washington State Ventilation Code. <br />5. The glazing and door U-value should be shown on the plans. 'fable 6-2 <br />Mechanical <br />Although the mechanical system is a separate submittal and review, the following items shcald be <br />addressed for this permit. <br />1. If the water heaters have nonrigid water connections and are over 4' in height, they should be <br />shown anchored or strapped to resist earthquake motion. Section 304.4, UMC <br />2 Combustion air supply should be provided to the gas -fired furnace and water heaters. The method <br />of providing and amount of air should be shown on the plans. Section 703.4 & 706, UMC <br />Domestic clothes dryers should be exhausted to the outside. If the combined horizontal and <br />vertical length of 14' is exceeded, high output dryers should be specified. Section 504.3, UMC <br />STRUCTURAL <br />The structural portion of this submittal is currently under review. The continents will be forwarded under <br />separate letter as soon as the review is complete. <br />Prepare a response letter showing where each item in this correction letter is addressed on the plan set. <br />Upon resubmittal of the drawings, your application will be given priority and plan review will <br />recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to ensure that the <br />proposed structure will be constructed in compliance with all adopted codes. <br />Sincerely, <br />Tony Lee <br />Associate Engineer <br />TLC,; I.Mkk.J) <br />cc: William Polk Associates <br />
The URL can be used to link to this page
Your browser does not support the video tag.