Laserfiche WebLink
if <br />Plan Check No. B59627 <br />October 15, 1998 <br />Page 2 of 3 <br />The toilet rooms should have the walls within 2 ft. of the front and sides of urinals and water <br />closets finished to a height of 4 ft. with a smooth, hard, non -absorbent surface such as concrete <br />or ceramic tile. Section 807.1.2 <br />An attic access opening (minimum 22 inches by 30 inches) should be provided with a minimum <br />clear headroom of 30 inches. The opening should be shown on the plans and be located in a <br />hallway, corridor or other accessible location. Section 1505.1 <br />Exiting <br />Panic hardware should be provided in exit doors serving the A-3 Occupancy. In lieu of this, <br />doors may have no locks or latches per Section 1007.2.5. <br />Two complying exit doors are required from the assembly space. Section 1004.2.3.1 & Table <br />10-A <br />The assembly room posted maximum capacity and location of the sign should be shown on the <br />plans. Section 1007.2.6 <br />/4. The two exits are not within the assembly room, exit signs will be required. Section 1003.2.8.2 <br />Accessibility <br />No toilet room elevations were located. The mounting heights of fixtures, grab -bars, etc. should <br />be noted on the plans for review. <br />,,toShowers should have lever -operating handles and a hand-held shower spray on a 60" long hose <br />mounted at a maximum of 48" above the floor. Section 1106.11.10.5 <br />The door to the office should be shown with 18" clearance next to the latch on the approach side. <br />Section 1106.10.3, item 1 <br />Drain pipes and hot water pipes should be shown recessed and insulated or guarded to prevent <br />contact. Section 1106.11.7.4 <br />Energy <br />The plan notes should indicate the chosen energy code compliance option for the building <br />envelope. <br />1 <br />