Plan Check Review Nos. B59674, B59674, B59676 <br />October 13, 1998 <br />Page 3 of 9 <br />02. The doors entering the stair enclosure in Building I from the pedestrian walkway from Building II <br />should be shown to be a minimum 90-minute assembly with a maximum temperature rise not to <br />exceed 450 degrees. Sections 409.7 & 1005.3.5.3 <br />C;31 he wall types shown on Sh:et A-5.0 should be keyed into the plans. <br />y� The wall type for the two-hour elevator shaft should be called out. <br />/ The listing for the two-hour wall type shown around the stair enclosure in Detail 2/A-8.0 should <br />be provided. Note that nonsymmetrical wall construction must comply with Section 709.5. <br />I 6�Wall construction Details 5, 6 & 7/A-5.0 show 1/2 inch GWB in rated assemblies. The listings <br />should be provided for verification. Additionally, each rated wall should have the listing shown <br />on the plans for field construction and inspection. Table 7-13 <br />07.The listing for the one -hour rated exterior balcony in detail 3/A5.0 should be provided. Section <br />1006.3.2.3 <br />It should be noted and detailed on the plans that penetrations of fire -resistive walls should be <br />protected for through and membrane penetration protection. Section 709.6.1 <br />9. It should be noted and detailed on the plans that penetrations of fire -resistive horizontal assemblies <br />shall be protected for through penetrations. Section 710.2 <br />1 Duct penetrations into the ceiling require fire dampers (ceiling rated) per Section 713.11. The <br />method of protection should be detailed on the plans - note that kitchen exhaust (stove) ducts are <br />not permitted to be equipped with fire dampers per the UMC. <br />Details J the guardrails including the height, spacing of members and structural attachments <br />0should be shown on the plans. Section 509 <br />12. lass I standpipes are required. The location should be shown on the plans. Section 904.5 <br />Fire protection is required during construction. The provisions of under Section 904.6 should be <br />noted on the plans. <br />_A! A draftstop is required in the attic such that the greatest horizontal dimension between draftstop <br />and ASW (or exterior wall) is not more than 100 feet. Section 708.3.1.2.1 <br />�. The location of the attic access opening should be shown for each attic space. Section 1505.1 <br />