My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1318 37TH ST 2018-01-02 MF Import
>
Address Records
>
37TH ST
>
1318
>
1318 37TH ST 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2021 11:06:08 AM
Creation date
3/31/2017 9:47:55 AM
Metadata
Fields
Template:
Address Document
Street Name
37TH ST
Street Number
1318
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
797
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C <br />Plan Check Review Nos. B59674, B59674, B59676 <br />October 13, 1998 <br />Page 4 of 9 <br />1 Safety glazing should be shown for the glazing at the stair landings in Detail 2/A-3.0. Section <br />/ 2406.4 <br />Safety glazing should be shown for the glazing adjacent to the sliding glass doors within the <br />dwelling units. Section 2406.4 <br />Safety glazing should be shown for the glazing adjacent to the tubs in the end units. Section <br />2406.4 <br />The plans should show that a listed smoke detector is placed near the elevator entrance that upon <br />f activation will prohibit the elevator from opening and shall return it to the main floor. Section <br />3003.2 <br />The minimum 3 square foot elevator hoistway vent should be shown on the plans. Section 3004 <br />Area Separation Wall <br />As there are no horizontal area separation wall provisions, the intent of the note showing one hour <br />fire protection at the ends of the ASW should be clarified. Section 504.6.4 <br />0'a <br />he area separation wall should be shown to completely divide the R-1 building into two separate <br />reas. As the exit balconies are floor area per the definition in Section 207, the ASW should <br />continue to the outermost edge of the buildings being separated. Section 504.6.3 <br />C3. <br />Openings within the ASW should be shown to be 90-minute rated, self -closing assemblies. <br />Sections 504.6.2 & 713.6.1 <br />4. The reference to Detail 4/5-10 on Sheet A 7.0 for the area separation wall should be revised to <br />Detail 9/5-10. <br />bSolid blocking to the width of the finished wall thickness should be shown where the top chord of <br />a floor truss penetrates the area separation wall in Detail 9/S-10. Section 504.6.1 <br />All roof plans should show the area separation wall locations, as well as the 10' wide zone where <br />no openings are permitted. Currently there appears to be a drain and ridge vent in that location. <br />Section 504.6.4 <br />'.7/The elevations show gable -end roof vents where an area separation wall occurs. These vents <br />should be relocated. Section 504.6.4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.