My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2410 38TH ST 2016-01-01 MF Import
>
Address Records
>
38TH ST
>
2410
>
2410 38TH ST 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2017 10:28:00 AM
Creation date
3/31/2017 10:27:38 AM
Metadata
Fields
Template:
Address Document
Street Name
38TH ST
Street Number
2410
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br /> � everett <br /> ,�� <br /> ; <br /> December 27, 1990 ��'��'�� ,1 <br /> � <br /> Patrick Pirtle � ihr I vrr�;rrrn <br /> ABKJ <br /> CIIY OF <br /> 220 West Flarrison <br /> Seattle, WA 98114 everett <br /> RE: Owner� Hill Street Investment <br /> Job Address 2410 38th Street <br /> Plan Check No. 90/26033 <br /> Dear Patrick: <br /> In response to your a�plication for a construction permit, your plans have <br /> been examined and you are advised that the issuance of a permit is being <br /> withheld for the reasons listed below. <br /> I /� The areas of the 2 buildings exceed the aliownble areas for Type V-N <br /> Vconstruction (UBC Section 505) . It appears that you sho�ld cnange the <br /> contruction to Type III-N. ��;_ i ;� �,;-- .. . ���, . � :�, ' ! r_: �; � 'J'�� ��:�� �, <br /> �� '� l� � � � �%''{ <br /> 1i% 2. Openings in exterior walls within 5 feet of �prupeFty lines (i.e. along <br /> ea�t p'ra�iep�y lline) are/� not �permitted ? . Openings less than 20 feet <br /> shqu�$ be�protected with Ci/4 hour f�re assemblir.s. UBC Section 2003(b) . <br /> ,,�Exterio�' s�3'� �:e. stuir no. 3) shall not project into an aYea where <br /> wall�./6�A'enings ;�re not permitted�"or must Ue protected: UBC Section <br /> 330��n) . <br /> ! 4. The exits of the first floor of the north building are required to have <br /> � a minimum separation of one-half the maximum overall diagonal of the <br /> buil3ing or area served measured in a straight line between exits. UBC <br /> � -�� Section 3303(0.) . <br /> . Stairway no. 1 should be separated from the warehouse by a one hour <br /> wall and 20 minute smoke door because the potential for fire is higher <br /> in the warehouse than in tlie office. All doors leading to the outside <br /> should he clearly marked as exits. <br /> �' `� 6, Restroom facilities for the physically handicnpped should be provided <br /> ��`� as set forth in Section 511 as follows: , <br /> ��" k ,7� <br /> c,°� �:.� � a. A clear circular space of 60 inch diameter within the toilet room. <br /> ,��,' Doors may encroach into this space by not more than 12 inches. <br /> �.` <br /> P <br />
The URL can be used to link to this page
Your browser does not support the video tag.