My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2410 38TH ST 2016-01-01 MF Import
>
Address Records
>
38TH ST
>
2410
>
2410 38TH ST 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2017 10:28:00 AM
Creation date
3/31/2017 10:27:38 AM
Metadata
Fields
Template:
Address Document
Street Name
38TH ST
Street Number
2410
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� • I <br /> / <br /> 2410 38th Streec <br /> December 27, 1990 <br /> Page two of three <br /> b. Grab bars shoLild be parallel �o and 33 to 36 inches above floor. <br /> Side grab bars should be 42 inches long with the front and <br /> pcsitioned 24 inches in front of the water closet stool. Grab bars <br /> at back should be at least 24 inches long for room installations and <br /> 36 inche� :ong where the water closet is installed in a stall. Grab <br /> bar diameters should not be less than 1-1/4 nor more than 1-1/2 <br /> inches providing a 1-1/2 inch clearance between the grab bars acid <br /> ad�acent surface. (Grab bars are not required in Group R, DLvision <br /> 1 apartment houses) . <br /> c. A clear space 30 inches wide, 29 inches high and 17 inches in depth <br /> shoul3 be provided under each lavatory. <br /> /d,�attom of at least one mirror sho�Qd he wi.thin 40 inches of the <br /> V floor. <br /> /7. Nonabsorbent finish and Uacking for toilet room Lloors, walls of toilet <br /> compartments, and walls around u�inals should conform with Section <br /> , 510(b) . <br /> /(L� �. The detaii of the scupper should be revised to meet '.ne requirements of <br /> ;� UBC 3207(c) . <br /> i 9. Structural calculations should be submitted to justify the adequacy of <br /> V the structural system (including foundation) for seismic, wind, dead, <br /> snow and live loads. <br /> J:O. Anchorage of cuncrete and masonry walls should comply with secCf.on <br /> l� 2310. Designs which rely on cross grain tension of wood members are <br /> not acceptable since the co3e has no allowable value. A positive maans <br /> of connection such as joist anchors or clip angles should be provided. <br /> See D�tails 1 & 6. <br /> � 11. Floor and roof diaphragms supporting concrete or masonry walls should <br /> �' have continuous cross ties between diaphragm chords in accordance with <br /> Section 2312(h)2H. Special anchorage of wood diaphragms should comply <br /> with Section 2312(h)2I. You may only need to verify subdiaphragm <br /> connections. <br /> (iY2. In Seismic Zones Nos. 3 and 4, minimum reinforcement s;iould be provided <br /> for masonry walls to comply with Section 2407(h)4B. <br />
The URL can be used to link to this page
Your browser does not support the video tag.