Laserfiche WebLink
�� 'f <br /> �� <br /> Plan Check No. 58910 <br /> June 4, 1998 <br /> Page 4 of 4 <br /> 33. Outdoor air is required to be supplied to all ha5itable rooms for all whole house ventilation <br /> systems. Specify the type of outdoor air sysiem including individual outdoor air inlets, <br /> forced-air heating system, ducting or equivalent means. <br /> 34. Note on the plans that outdoor air inlets shall not be placed in the following locations: <br /> a. closer than 10' from an appliance vent oudet, unless such vent outlet is 3' above the <br /> outdoor air inlet. <br /> b. Where it will pick up objectionable odors, fumes or flammable vapors. <br /> c. A hazardous or unsanitary location. <br /> d. A room or space having any fuel-burning appliances. <br /> Prepare a response letter showing where each item in this correction letter is addressed on the plan <br /> set. <br /> Upon resubmittal of the drawings, your applica[ion will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient � i:�l and contain sufficient informauon to ensure that the <br /> proposed structure will be cerstructed in compliance with all adopted codes. <br /> Sincerely, <br /> �.�_ � <br /> J ff�n � <br /> Deveiopment Technician j <br /> IIl:jndycG•�r.plck.l) <br /> � <br /> � <br />