Laserfiche WebLink
,r- ... <br /> :f,'--' ., . <br /> .,�.,:v. <br /> P��L�� I�/b//6/i.3' <br /> a'�.� �',T ir <br /> June 2, 2002 <br /> Jack Sheeler <br /> 8919 Eastview Avenue <br /> Eve;ett, WA 98208 <br /> RE: Owner: Sheeler <br /> Job Address: 2408 39`h Street <br /> Plan Check No: B0305-036 <br /> Dear Mr. Sheeler: <br /> In response to your application for a construction permit, your plans have been examined and you are <br /> advised that the issuance of a permit is Ueing withheld For the reasons listed below. These commen[s <br /> address building issues only. Additional revisions, or additions, may be required by other <br /> departments (such as Utilities, Plannin� or Fire). All references refer to die 1997 Uniform Building <br /> Code, as amended by the State of Washin�ton and/or Washingtcn State Energy Code, 2001 Edition, <br /> unless stated othenvise. <br /> In order for the processing of your application to continue, it will be necessary to provide tlie <br /> Building Division with two complete new sets of drawings retlecting the corrections requested. <br /> I. The submitted post desi�n includes a design moment of WL�/S. This implies that the posts <br /> are laterally supported at the top, which implies that the latera( stabiliry of the building <br /> depends on shear transfer throu�h the roof diaphra�m and into shear walls. Raof diaphragm <br /> and sheanvall desi�ns must be provided clearly definin� the load path to the ground. <br /> Allowable shear values and corresponding fastening requirements must be provided from the <br /> roofing and siding manufacturers. Post calculations must be as required by the 1997 UBC. <br /> Rough sawn lumber must be specified if nominal dimensions are to be used in Ihe <br /> calculations. <br /> 2. 1'he submitted calcula[ions for the truss to post connection indicate a value of 1200 Ibs. for a <br /> 3/a" bolt in single shear parallel to the grain with '? x side pieces. The 97 UBC indicates a <br /> value of 720 lbs. for this condition. Please revise calculations and c,arify detailin� in the <br /> construction documents. <br /> 3. The submitted calculations for the girts indicate an allowabfe bending stress of 1.25 ksi. This <br /> does not a�ree �vith any of the 97 UBC listed values for hem fir. Please revise the <br /> calculations and use 97 UBC stresses and adjustment values. Lumber grades must be <br /> indicated in the construction documents. <br /> 4. The submitted calculations for the purlins indicate a desi�n moment of WL'/11. Piease <br /> explain. Provide the intended grade of hem fir and use 97 UBC allowable stresses and <br /> adjustment f.:ctors. Lumber�rades musc be included in the construction documents. <br /> DEDVPL\C1:?ISTR011LL[RNO:A5�076�2�U979'"STI / � <br /> � � �,F �VFRETT• 3200 Ceaar St•�.e: • E . . _.. .' • - � ; -_g���.� • F�;�. �_ - _,.�'- <br />