Laserfiche WebLink
hour fire resistant partitions, per IE3C sectiors 420.?_, /09.3, and the continuity requirements <br /> of IBC section 709.4. Not completed in resuGmitta/. <br /> 3. The horizontal separation between Units A and B (should be referenced on the drawings to <br /> floor sections indicating teste_d_floo_r assemblies to meet the requirements of one how�fire <br /> resistant horizontal assemblies, per IBC sections 420.3 and 712, and the continuity <br /> requirements of I6C sectiun 712.4. Not comp/eted in msubmittal. <br /> 4. The garage should be marked on the plans. The new wall separeting the 9arage from the <br /> stair and existing walls, ceilings and doors should be shown on the drawings to comply with <br /> IBC sedion 406.1.4. <br /> Egress <br /> 1. The new interior stair treads and risers should be coordinated on the drawings;_the treads <br /> are indicated a_s 10, ].1 and 12 inches on the drawin s_The length of run of should be <br /> revised to match the actual tread d_epth. Tne Floor to Floor height should be shown to verify <br /> the riser height shown on the drawings. Not comp/eted in resubmitta/. <br /> 2. Continuous handrails should be shown on one sidE of the new interior stair plan on the <br /> drawinqs, per IBC section 1009.12, exception 2. Not comp/eted in resc;bn�itta/. <br /> 3. The profile of the interior stair handrail should be_shown on the drawinqs to meet the <br /> graspability of Type I handrails, per IBC section 1012.3.1. Notcamp/eted in <br /> resubmitta/. <br /> 4. Each bedroom should indicate an emergency escape and rescue window opening, mee[ing <br /> the requirements of IBC section 1029.1, with a reference to an elevation of the window <br /> meeting the requirements of I3C section 1029.2. Not con�pleted in resubmittal. <br /> 5. Single- or multiple-station smoke alarms sho�ld be shown on the drawings on the ceiling or <br /> wall ouside of each separate sleeping area in the immediate vicinity of bedrooms, �n each <br /> room used for sleeping purposes, and in each story within a dwelling unit, per ?�C section <br /> 907.2.11.2. Currently_shown with the same symbol as fan._Either note_on dra_wings_or <br /> create a separate�mbol. Not completed in resubmittal. <br /> 6. Note: smoke alarms will require an electrical permit application. <br /> These comments address building issues only. Revisions or additions may be required by other <br /> departments (Utilities, Public Works, or Planning). Code references cited ir+clude the 2009 <br /> International Building Code (IBC), the 2009 Washington State Energy Code (WSEC), and the 2003 <br /> Accessible and Usable Buildings and Facilities A117.1 (ICC/ANSI). All codes referenced, as <br /> adopted by the City of Everett, should include current revisions by the State of Washington. <br /> All required submittals must be of sufficient detail and information to ensure that the proposed <br /> structure �vill be constructed in �omplianc� �vith all adopted cooes. Pleas� contact me with any <br /> questions at 425-257-8813. <br /> Si erel <br /> Me H ley, Plans Examiner Attachments <br /> _ � <br />