Laserfiche WebLink
PUBLIC WORKS PERMIT COMMENTS <br />Connect side sewer per City Standard #601. <br />Connect side sewer per City Standard #'s 601, 602, 604. <br />Connect ail rooftop downspouts to the side sewer. <br />Connect rooftop downspouts to the drainage system provided for this lot. <br />8. Rooftop runoff must be discharged to a roof downspout infillration systam per City of Everetl Storm <br />Manual 3-2.6.2. The approximate size trench is 3.5' wide, 2' deap and 25' long. See attachment for <br />more details. <br />� The contractor must meet wilh the Public Works Inspector to dis� ,s� potential drainage routing prior lo <br />beginning the project. <br />10. Install erosion control measures as determined by the Public Works inspector, such as silt fence, straw <br />bales, swales, or erosion blankets. <br />11. Instail erosion control measures per City of Everett Standards for small parceis <br />12 Remove erosion control measures upon completion of the projact prior to final approval of the permit. <br />/93. ) All excavated materiai from foundation, sidewalk and driveways shall be hauled to an approved, <br />L� permitted site. No wasting of material is allowed on this building lot. <br />14. <br />15. <br />16 <br />17. <br />No dirt, mud, rocks or debris to be tracked onto roadway. <br />No building materials to be stacked on sidewalks and sidewalks to be kept clean and open for <br />pedestrian travel. <br />Adjust water meter box 1" above sidewalk grade. <br />Remove and replace curb, gulter and sidewalk as per Cily of Everett Standard Plan #'s 305A & 306 on <br />this proposal's frontage as directed by the Public Works Inspecior (i.e. all unused driveways and any <br />broken or damaged area must be replaced). <br />Inslall a Type I concrete driveway per Ciry of Everett Standard #307. <br />Pave driveway from the (ront property line oul to the street paving. <br />20. Contact the _ <br />sewer services. <br />21. <br />22. <br />23. <br />Water District for connecting provisions for this building's water and <br />A catch basin as per City Standard Plan #402 with a gas trap pnr Standard Plan #410 is required for the <br />parking area. <br />If a sewer pump system is to be installed, the pressure line must discharge into a private manhole, then <br />gravity (low across the public right-of-way. <br />A sprinkler system is required for this building in cornpliance with the requirements of NFDA Standards <br />13D. <br />PWCommen(s <br />i <br />—, •i <br />