My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1410 51ST PL SW 2016-01-01 MF Import
>
Address Records
>
51ST PL SW
>
1410
>
1410 51ST PL SW 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2017 6:51:58 PM
Creation date
3/31/2017 3:22:37 PM
Metadata
Fields
Template:
Address Document
Street Name
51ST PL SW
Street Number
1410
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBL/� K/O �" <br />July 15, 1991 <br />Peter C. Held <br />1410-Slst P1. S.W. <br />Everett, WA 98�03 <br />RE; Ownei: Peter C. Held <br />Job Address 1410-Slst P1. S.W. <br />Plan Check No. 91/27171 <br />Dear Mr. Held: <br />a ^ + <br />(� t,� J i� , <br />� <br />� <br />In response to youz application for a construction permit, your plans have <br />been examined and you are advised that the issuance of a permit is being <br />withheld for the reasons listed below. <br />1. Plan set does not include floor plan for main level showing: <br />,/l Bathroom Addition <br />}�. Existing layout of area below addition. Indicate existing walls <br />and call out new beams and/or headers. Show any walls to be <br />removed, altered or added. Label all spaces (i.e., kitchen, <br />bathroom, etc.). <br />fL. All openings in existing exterior walls (for lateral bracing <br />requirements). <br />� Site Plan does not show proposed bathroom addition. <br />� Site plan does not show proposed cantilever at upper level. <br />,!l Proposed bedroom does not provide sufficient natural light and <br />ventilation"per Section 1205 UBC without utilizing glazing in french <br />door. Provide minimum 1/10 and 1/20 of floor area for natural <br />lighting and natural ventilation respectively. <br />� Staizways are required to have a minimum 36" landing, measured in <br />the direction of travel, at the top and bottom of the stairs. <br />j� Each water closet stool shall be located in a clear space not less <br />than 30 inches in width and have a clear space in front of the water <br />closet stool of not less :han 24 inches. Section 511 UBC. <br />CITY OF EVERE'T: • 3200 Cedar Street • Everett. WA f�6201 •(206) 259-8800 • Fax (206) 259-8882 <br />
The URL can be used to link to this page
Your browser does not support the video tag.