Letter for Plan Check No. 91/27171 <br />Page 2 of 2 <br />� Plan set do��s not include roof framing plan (may be shown on upper <br />level floor plan). Show direction and spacing of roof trusses. <br />� Second floor plan xuns off top of page obscur .tg dimensions on that <br />portion of addition. <br />� In all habitable rooms, receptacle outlets shall be installed so <br />that no point along the floor line in any wall space is more than 6 <br />feet, measured horizontally, from an outlet in that space S.ncluding <br />any wall spaca 2 feet or more in width per Section 210-52 National <br />Electrical Code. <br />i <br />j�t1. Foundation plan dc�s not call out beam size or size and spacing of <br />existing conc piers and posts at center of structure. Provide beam <br />size species and grade at existing beam. <br />i <br />�. Plan set does not include information on how guardrail at stairwell <br />is constructed, Provide detail of guardrail cons:ruction. Open <br />guardrails shall have intexmediate rails or ornamental pattem such <br />that a sphere 6 inches in diameter may not pass through. Section <br />' 3306 ( j ) UBC. <br />32� Provide 1 1/2" - 2" diamater har;drail placed 34" minimum - 38" <br />maximum above tread nosing. <br />In order for the processing of your aF�plication to continue, it will be <br />necessary to provide the Building Department with two complete new sets of <br />drawings reflecting the corrections requested. <br />Upon resubmittal of the drawings, your application will be given priority <br />and plan review will reco�ence. <br />All of �_he above information shall be of sufficient detail and contain <br />suf£icient infoimation to ensure that the proposed structure will be <br />constructed in compliance with the City Building Code. <br />Sections shall be applicable to plan submitted. <br />Sincerely, <br />q����- <br />Jeff Heilman <br />Engineering Technician <br />JH:jtb/11-17 <br />I! <br />� <br />