My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
415 51ST ST SW 2016-01-01 MF Import
>
Address Records
>
51ST ST SW
>
415
>
415 51ST ST SW 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/24/2017 4:56:06 PM
Creation date
3/31/2017 3:38:06 PM
Metadata
Fields
Template:
Address Document
Street Name
51ST ST SW
Street Number
415
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DXKEMAN <br />IYSPIRING tVEPYI)AY SPAl:F.S <br />Novembcr 14, 2003 <br />Mr. JefT'Heilman <br />Development Technician <br />Ciry of Evcrctt Public Works <br />Engineering / Yublic Services Depanmen[ <br />3200 Cedar Street <br />Everett, WA 98201 <br />Dear Mr, Heilman: <br />a L�����%[� <br />NO V 1 y T003 <br />«D <br />..�iry....oF..Ev�;���,-T ... <br />�'ermit Servi�ea <br />RE: Permit Plan Review Camments <br />Larsen Residence <br />415 51" Strect SW, Gverett, WA <br />Plrn C6eck No.: C0310-023 <br />Dykeman Project # 2003-042 <br />orrhlurturr <br />���.,o,, a.,�x� <br />nia��i�x <br />The following is our rcs�nse to your plun review comment letter dated November 5, 2003 regarding the <br />above referenced project. We have typ�:d your comments and numbering format here for cefrrence with <br />our res�nse in lwld type facc. This along with two complete sets of plans with apdates denoted by delta- <br />1 and clouded as requested referencing Ihis infonnaticn. <br />I. The Plans as drawn do not meet the prescriptive requirements for lateral bracing. Provide lateral <br />analysis pmpared by u licensed Wushington State Strur.turt+l Engineer. <br />Notes hrve been updated to show this information oo Floor Plan Sheet A-1 and Wrll Scctions, <br />on Sheet A-3. Refer Also ro Structunl Calculations sttec6ed from RB Engineering dated <br />11.14.03. <br />2. Provide smoke detectors in ull sleeping rooms and in the corridor or area Siving access to each <br />scparatc slccping arca. <br />This information is now re[erenced in general note number S on the TiNe sheet T-1. <br />3. 2001 Washington State Gncrgy Code (WSEC) requires R-38 in the ceiling, R-21 in the walls and R- <br />30 in the tlooc 2xR Ooorjoists do not provide suflicient depth lor R-30 batt insulation. Insuletion is <br />rcquired to bc in substantial cont¢ct with the heated surface and permanenUy supported at not morc <br />thun 24" o.c. <br />Insulation R-values have been reviseJ un sheet T-1, Energy Notes #4 rnd revised at Building <br />Sections on Sheet A-3. We have increase wood [loor joists froro 2:8 to 2:10 to obtsin an R-30. <br />4. Specify size nnd spacing of bolts at Iedger attachment to existing rimjoist. <br />Note has revised on Building Section 1, on Sheet A-3. <br />5. Specify 'h" x 10" A.Ei. L 48" o.c. 7" minimum embedmenL Minimum two (2) each piece and within <br />12" of each end of each picce. 2"x2"x3/16" plate washer required un al! anchor bolts. <br />Note has been updnted ta show this information on Building Section 1, on Shcet A-3. <br />6. Insulation baf0e shall extend 6" vertically above butt insulation and 12" vertically above loosc fill <br />insulation. Show reyuirement on plans. <br />Notes huve been updated to show this information on Building Sections, on S6eet A-3. <br />7. Spccifp conncction of new foundation to thc esisting foundation. <br />Notes have been added to �how this information on Psrtial Foundation Plan, on S6eet A-(. <br />_ _ — _ _ — —_ ____ _ — ._ _ _... — - ----- <br />�rl: �2i 25!I.17U1 /na: �25.259.5:�:� u�ivw.Jyknnun.nrr 171fi N'e�l Na�lne Vlew Urive F:veroll, WA 98201-209B <br />
The URL can be used to link to this page
Your browser does not support the video tag.